Does it give you an error code when it jumps out of gear?
Do you have the tech code to get into the display?
if so try to recalibrate the transmission valves.

Heavy Machinery | Answered 3 hours ago


This is an injector driver code.
injector driver module has failed
ECU failed
injector shorted to battery voltage
may need to reflash VSM

Heavy Machinery | Answered 3 hours ago


I would try putting lift hose on the down side and down hose on the lift side. If it lifts when you push the down control and does not go down when you use the lift control then it may be a spool problem. Always take care to control all forms of energy when removing hoses to prevent harm or *****. I'm not sure if the spool on your loader is pilot controlled or mechanical linkage?? If it is mechanical take a look at all linkage and make sure its moving correctly. If its. Pilot control then the issue may be there also. Good luck and be safe.

Heavy Machinery | Answered 23 hours ago


Almost always the fuel filters. If the filters have been changed and the air is removed from fuel system it may be the pump. There should be a primer bulb in line with the fuel hose coming from the tank. Give that a squeeze and it should get hard if you have fuel pressure. If the primer bulb collapses when the machine dies that means there is something inside the suction tube located inside the tank. I have had this happen many times. You have to remove the suction tube from the tank to clean it out. DO NOT BLOW AIR INTO THE LINE. Good luck.

Heavy Machinery | Answered 24 hours ago


If no hydraulics are operating then there may be a few things to look at. Check the hydraulic fluid level as drive and bucket controls are hydraulic based. The hydraulic pump is shaft driven by the hydrostatic pump. If the fluid level is not proper, this could cause symptoms. Air in the system is another factor but most systems are self purging.

There are filters in various points around the unit and are 40 micron. Main filter has s bypass should filter be clogged. However, the smaller filters do not. The hydraulic system stays at charge pressure and fluid flows through control valves until actuated. If a spool is stuck, it may be bypassing fluid not allowing pressure to build up. Should give a basic starting point to troubleshoot further.

Heavy Machinery | Answered 24 hours ago


Download Hyster Manuals
Visit The Link:
1- https://sellfy.com/heavyequipmentmanuals
2- https://heavy-equipmentmanual.com/
3- https://heavy-equipmentmanual.com/
E-Mail: victordieselmechanice@gmail.com

workshop-service-repair-manual-xi0wf24eevrfg3fcwvgdcsig-1-0_0.jpg

Atlas HYSTER... | Answered 3 days ago


Google (brand)(CSV-2515)(manual) without parens OR contact the manufacturer/distributor directly to inquire.

Heavy Machinery | Answered on Oct 06, 2019


If the pedal you are talking about is deadman switch, either FOD has rolled in under pedal and lodged orbit is time to get a replacement pedal

Heavy Machinery | Answered on Oct 01, 2019

Not finding what you are looking for?
Heavy Machinery Logo

2,322 questions posted

Ask a Question

Usually answered in minutes!

Top Heavy Machinery Experts

Brad Brown

Level 3 Expert

18108 Answers

STEVE

Level 3 Expert

30301 Answers

ray gallant
ray gallant

Level 3 Expert

64234 Answers

Are you a Heavy Machinery Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...