I have problems with whirlpool refrigerant the compressor not working no any electric power came to it that for I checked all the ather thing it's ok and the out fan behind the compressor it usually working.
My question is what the main thing to make compressor not working in the same time fan are working.

Whirlpool... | Answered on Oct 17, 2019


Hi,

As the weather is getting warmer for many people their freezer2_bing.gif and/or refrigerator do not work right because of a dirty condenser coil...

Check out this tip that I wrote about that... it is a great place to start trouble shooting your unit...and something that you can do rather then calling a repair person to do a simple thing for you...

Refrigerator2_bing.gif Condenser Coil Cleaning Refrigerator2_bing.gif Repair
http://www.fixya.com/support/r4024657-refrigerator_condenser_coil_cleaning

Refrigerator Troubleshooting2_bing.gif Refrigerator Compressor
http://www.fixya.com/support/r3885294-refrigerator_troubleshooting

Refrigerator Compressor Start Capacitor and Start Relay
http://www.fixya.com/support/r4023749-refrigerator_compressor_start_capacitor

heatman101

GE Profile... | Answered on Oct 17, 2019


Thermistors input temperatures to the control boards. Thermistors may have a 2k Ohms value at 70° F, a service manual or guide, or look up part number for replacing any thermistor out of range.

Kenmore... | Answered on Oct 16, 2019


Check the line that goes from the water pipe to the back of the refrig. Someone may have used something they shouldn't have. The lines in the refrig won't break down like that.

LG Refrigerators | Answered on Oct 16, 2019


Often it's the gears that become bad. See if you can get a new gear set or call in an appliance repair service to install or at lease check it out.

Refrigerators | Answered on Oct 16, 2019


Probably the unit is trying to fill because the on/off bar it down (senses the level of ice in the tray). Lift it up to turn off.

Refrigerators | Answered on Oct 16, 2019


To have the model number would be very helpful to give you the correct information.

Kenmore... | Answered on Oct 16, 2019


CALL A LOCAL REPAIR SERVICE THE DAMPER MOTOR MAY NEED REPLACED

Refrigerators | Answered on Oct 16, 2019


Set it initially to 5, then adjust after 8 hours as needed. If the regular liquids (not alcohol) start to freeze in the fridge section, it's too cold!

Refrigerators | Answered on Oct 16, 2019


In the freezer compartment there is a panel on the ceiling of the freezer, remove this with a small spatula, it snaps off, there is a dial that controls the airflow on the panel, inside this panel is the defrost control board, it does not use the old time defrost timer, it uses this part, its about $250
Cntrl-Elec Part Number: AP6023580 Made by: Genuine Whirlpool part OUR PRICE $259.12 REGULARLY YOU SAVE $260.53 $1.41

Whirlpool... | Answered on Oct 16, 2019


39E is a bad ice maker as you know. Try to heat up the ice maker with a hair dryer in case ice has jammed the ice maker from rotating properly. If it still doesn't work, the entire ice maker would need to be replaced I'm sorry to say. '

So error 40E means your ice maker fan isn't running properly and 24E means your freezer isn't defrosting properly. Both items are inside the freezer behind the back wall. You'll need to pull everything out of the freezer and remove the entire back wall inside the freezer. Thaw any ice or frost built up you see with a hairdryer. Re-install everything and then on the dispenser press and hold the upper right and upper left buttons to reset the error codes. If everything resets, then great. If it won't reset, then you need to replace your defrost temperature sensor clipped onto the top of the silver coils behind the back panel you removed, and you also need to replace the ice fan motor.

Samsung... | Answered on Oct 16, 2019


Filter may have been installed backwards

Samsung... | Answered on Oct 15, 2019


POSSIBLY NEEDS A NEW AIR DAMPER MOTOR CALL A LOCAL REPAIR SERVICE

Refrigerators | Answered on Oct 15, 2019


With a miniscule leak, it is not easy to detect with liquid type detector, a halogen leak detector may or may not detect it.
What after a leak is detected, it needs to be patched, soldered, but refrigerant would need to be removed first.
You may install a tap on service port, it clamps on the line and no soldering required.
With normal operation, the top 2/3 of the condenser coil is hotter than the bottom 1/3 of the coil.

Refrigerators | Answered on Oct 15, 2019


what is elcb

Refrigerators | Answered on Oct 15, 2019

Not finding what you are looking for?
Refrigerators Logo

173,269 questions posted

Ask a Question

Usually answered in minutes!

Top Refrigerators Experts

John Tripp
John Tripp

Level 3 Expert

4656 Answers

Marvin
Marvin

Level 3 Expert

85206 Answers

Brad Brown

Level 3 Expert

18108 Answers

Are you a Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...