Harness or connectors (The sensor circuit is open or shorted)
- Front Heated oxygen sensor (Bank 1) may be faulty
Possible Solution
Replacing the O2 Sensor 1 usually takes care of the problem
P0135 Description
The
front heated oxygen sensor (or sensor 1) is placed into the exhaust
manifold. It detects the amount of oxygen in the exhaust gas compared to
the outside air. The heated oxygen sensor 1 has a closed-end tube made
of ceramic zirconia. The zirconia generates voltage from approximately
1V in richer conditions to 0V in leaner conditions. The heated oxygen
sensor 1 signal is sent to the ECM. The ECM
adjusts the injection pulse duration to achieve the ideal air-fuel
ratio. The ideal air-fuel ratio occurs near the radical change from 1V
to 0V.
When is the code detected?
-
Current amperage in the front heated oxygen sensor heater circuit is
out of the normal range. (An improper voltage drop signal is sent to ECM through the front heated oxygen sensor heat a four thumbs up would be helpful if this fixed your problem thanks have a nice day
339 views
Usually answered in minutes!
×