2004 Pontiac Grand Prix Logo

Related Topics:

cory Posted on Mar 15, 2017

2004 Pontiac grand prix blower motor.... I had a problem with the blower motor running when the car was off...replaced the control module...now the blower motor isn't working at all. Had this problem before. Took motor apart and greased the brushes. Work good but figured wouldn't last long. I now bought new blower motor and still nothing. Is there anyway water could be leaking down around the cowl and got to the module that i just replaced and it is bad again. I checked the cabin filter and the little rain gaurd was off so I re-installed it. Also...several times down there messing with the wires out of the module to the motor...it would kick on for a second. Have power going to the module on the red and black wire...dont know how the test from the switch..just know there is power going to the module..but not out....please help....thanks

4 Related Answers

Anonymous

  • 132 Answers
  • Posted on Jul 30, 2008

SOURCE: 2000 Pontiac Grand Prix interior fan speeds 1-4 not working

Check the ground, the resistors are accully resisnting the Negitive Current.

Ad

Anonymous

  • 1 Answer
  • Posted on Mar 03, 2010

SOURCE: pontiac grand am leaks water into front floorboard when it rains

I had the same problem on my 97 G AM for about a year now, Water getting on the driver side carpet all the way to the back,it just got worst over time, But I found the problem, you have to look behind the wiper motor where the fire wall meets the bodi ,there is a hire line crack rigth behind the wiper motor where the water coming from the wiper cowling drains from ther is some kind of coulking that is painted the same color as the car, you must clean the area with a screwdriver and soap, and use clear silicon with a coulking gun, you must remove the 2 top wiper motor screws do not remove the botom one not need to and remove the 2 wire plugs and pull the motor back and rotaded upwards know youre clear to do the job; good luck it worked for me.

Anonymous

  • 335 Answers
  • Posted on Jun 20, 2010

SOURCE: My 1997 grand prix leaks through the blower motor

Hello, you will need to install a part called a deflector.

here is a picture and the part number

15212454
Deflector-Plenum Water
15212454
Deflector-Plenum Water

15212454
Deflector-Plenum Water



aee51ba.gif

JOSHUAJBARTH

  • 57 Answers
  • Posted on Jul 11, 2010

SOURCE: 2004 Pontiac Grand Prix GTP front pass turn signal doesn't work

you would need to buy a blinker relay

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

How do I remove and install heater blower motor

04-08 Pontiac Grand Prix - Blower Motor Resistor ... - YouTube

? 7:32
https://www.youtube.com/watch?v=Cn0HeJP8bZQ
Oct 8, 2012 - Uploaded by GPVlog
04-08 Pontiac Grand Prix - Blower Motor Resistor ReplacementPart 1 ..... Loosen, but do not remove the two frontward screws, then remove the single rearward .... Pontiac Grand Prix StereoRemoval 2004-2008 - Duration: 4:27. by Factory Car Stereo ...Pontiac Grand Am ,HVAC, Heater Fan will not turn on.

04-08 Pontiac Grand Prix - Blower Motor Repair (Part 1 ...




0helpful
1answer

I have a 2004 Pontiac Grand Prix GT. New relay and blower motor, still no air blowing. What should I do now?

Replace your blower motor control module, aka blower resistor. Try applying 12volts directly to blower motor to make sure it's not defective first.
0helpful
2answers

2006 Grand Prix GT blower motor stops working on start up in cold

Rather then rigging it , fix it right ! The blower motor could be bad . Testing the electrical circuit , checking current draw , voltage drop . etc.... Hooking up a light switch isn,t going to keep it on if parts are failing . More then likely the blower motor control processor is going bad . The blower motor is electronically controlled .
HVAC Blower Motor Circuit

https://www.1aauto.com/2006--pontiac-grand-prix-blower-motor-module-for-models-with-automatic-temperature-control/i/1ahbr00026?f=489143&y=2006&utm_source=bing&utm_medium=cpc&utm_campaign=Shopping%20Campaign%20F-L%20-%20Medium&utm_term=1100309270240&utm_content=F-L
2helpful
1answer

My blower motor won't shut off

I had the same issue. Brought it back to dealer and they replaced the blower itself. Below is the bulliten


Models:
2005 Buick Allure (Canada Only), LaCrosse
2004-2005 Pontiac Grand Prix

Supercede:
This bulletin is being revised to update Step 5 of the service procedure. Please discard Corporate Bulletin Number 05-01-39-001 (Section 01 - HVAC).
Condition
Some customers may comment on an inoperative or intermittent Heating, Ventilation and Air Conditioning (HVAC) blower motor. Others may comment that the blower motor speed may momentarily drop or that the blower motor continues to run after the key is turned off.
Cause
This condition may be caused by a voltage spike from the wiper motor. The voltage spike may cause a logic lock up in the blower motor control module that may be either momentary or permanent.
1helpful
2answers
0helpful
1answer

Vent fan is not shutting off

The blower motor speed control module is most likely shorted. This is very common on the gm w-body cars such as your grand prix.

Order and install a new blower motor speed control module and install. It is located in the hvac box, passenger side, near the blower motor.
1helpful
2answers

Replace blower motor Grand Prix

Grand Prix has problem with resistors module, replace it, will fix problem 99%
Not finding what you are looking for?

140 views

Ask a Question

Usually answered in minutes!

Top Pontiac Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Thomas Perkins
Thomas Perkins

Level 3 Expert

15088 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Pontiac Expert? Answer questions, earn points and help others

Answer questions