Kyocera Mita KMR-1810P Laser Printer "fuser thermistor" Questions

Ad

Question about IBM Office Equipment & Supplies

1 Answer

...thermistor check failure. Fuser page count between 0 and 99,999. ? Noisy thermistor signal. ? Intermittent connection. ? Thermistor cable not connected or thermistor actually open. Go to ?924.xx?Hot ...

Ad

Question about Panasonic Office Equipment & Supplies

1 Answer

...Fuser Thermistor dirty. 2. Thermistor position incorrect. 3. Thermistor defective. 4. Thermistor connector disconnected. 5. Fuser Lamp connector disconnected. 6. Fuser Lamp defective. 7. Fuser ...

Ad

Question about Kyocera Mita Office Equipment & Supplies

1 Answer

...fuser thermistor S temperature *35/37 and 45/47 ppm printers (EUR/USA model) only The temperature of the fuser thermistor S detects 250°C/482°F or more continuously for 3 s. ...

...fuser heat roller. Check the wiring to the thermistor assembly. Check the wiring to the NC thermistor, PL 10.28 Item 19. Install new components as necessary, PL 10.28. 5. Check for continuity between ...

Question about Kyocera Mita Office Equipment & Supplies

3 Answers

fuser thermistor M wire *35/37 and 45/47 ppm printers (EUR/ USA model) only Input from fuser thermistor M is less than 1 (A/D value) for more than 3 s. Poor contact in the fuser thermistor M connector

Question about Kyocera Mita Office Equipment & Supplies

1 Answer

...either disassembling the fuser and replacing the thermistor ( if you can find one) or replacing the fuser assembly. so i would suggest that take it to nearest service centre of lexmark. best of ...

Question about Panasonic Office Equipment & Supplies

1 Answer

...Fuser Thermistor is dirty. 2. Thermistor position is incorrect. 3. Fuser temperature is low. 4. Thermistor is defective. 5. Fuser Lamp connector is disconnected. 6. Fuser Thermostat is defective. 7. ...

Question about Kyocera Mita Office Equipment & Supplies

1 Answer

...device Fuser thermistor (middle front) - thermal control device Fuser thermistor (rear) - thermal control device These items wear out. Change at the same time. Fuser needs to be rebuilt or

Question about Office Equipment & Supplies

1 Answer

...fuser thermistor 1 reaches primary stable temperature after a warm-up start and the fuser thermistor 2 is less than 90 ° C/194 °F. Causes Fuser unit. Main/Engine PWB. Power source PWB. Fuser

Question about Office Equipment & Supplies

2 Answers

...Fuser thermistor 10-302 Low fuser temperature 010-304 Bad fuser temp 10-308 High fuser temperature or open thermistor 010-310 High fuser temperature 010-312 Fuser not up to temperature after energy ...

Not finding what you are looking for?
Kyocera Mita KMR-1810P Laser Printer Logo

35 questions posted

Ask a Question

Usually answered in minutes!

Top Kyocera Mita Office Equipment & Supplies Experts