TD sensor error The BICU detects the TD sensor outputting abnormal voltage (less than 0.2 V or more than 4.0 V) 10 times consecutively. ? Defective TD sensor ? Loose connection of the PCU you may need
Question about Ricoh Aficio Office Equipment & Supplies
...TD SENSOR FAULT, CHANGED WITH ANOTHER 2ND HAND UNIT I KNOW WAS WORKING FINE BUT DRUM WAS WORN ON EDGES, STILL SAME FAULT? THEIR ARE NO SEAL BEEN LEFT IN UNITS. PLEASE HELP. ? Someone forgot to remove ...
...TD sensor abnormal · Drum does not turn · Development roller does not turn · Poor connection of the PCU Regards, the problem is in the development unit. check for contact points Its a ...
Question about Ricoh Aficio Office Equipment & Supplies
...either replace the TD sensor by itself, or replace the DV unit (which probably won't be much more expensive). But either way, you'll need to install new developer when you replace the
...TD sensor is a electronic sensor that is short term from T-toner & D-density, so the Toner Density sensor is at is says Detects and measures how much and does have a toner in the developer
aficio 550 with error code 390-3 how to fix it? That denotes a defective TD sensor. The sensor may need replacing and the developer will need to replaced and initialized with it.
what does sc392 mean on a mp2510 Someone forgot to remove the tone seal of the PCU ID sensor defective TD sensor abnormal Drum does not turn Development roller does not turn Poor connection of the PCU
error sc 366 TD sensor: Output minimum error [C] Defective connector connection Decreasing toner density 1. Replace the CYAN PCU.
SC366 on SP410DN This is a TD sensor output error. Causes: Defective connector Decreasing toner density Replace the Cyan PCU.
error sc364 Check all TD sensors connections to the PCU. Or else replace PCU