Fusing unit is not set properly I replaced the fusing unit and when I turn the printer back on, I get this message : "Fusing unit is not set properly". Any idea ? The old one and the new look the same
...fusing unit error I replaced the fusing unit in my ap3800c today but am now getting an error message "replace fusing unit type c" which has also locked the machine. I am unable to get into the ...
Question about Ricoh Aficio Office Equipment & Supplies
...Fusing thermostat open ? Power supply board defective This condition be clear when entering to service program mode press "Total Clear (yellow key) 1 0 7 and to maintain presed the clear stop key ...
Question about Ricoh Aficio Office Equipment & Supplies
fusing unit connector may be loose. u can reset the error by entering the service mode (careful -do not change anything ) to enter the service mode press [all clear](yellow button) ,[1],[0],[7],[clear
...fusing unit, touch yellow/clear key then press 1 0 7 and hold down "Stop" key for 10 second. LCD screen will change, turn off the machine from the main switch (not the top panel switch) wait for five ...
Question about Ricoh Aficio Office Equipment & Supplies
...clear this SC548: Fusing unit installation error - Definition - [A] The machine cannot detect the fusing unit when the front cover and right cover are closed. - Possible causes -· Fusing unit is ...
...fusing unit I have replaced the fuser and still have the same error. Press total clear press 1 0 7 and press for more off 3 second the clear stop key to enter to service program mode. Then enter SP ...
...fusing unit connector,thermistor warped or broken,thermostat has tripped,power supply defective.After verify the componenets try reset the error.Enter in service mode:Press the yellow key and press ...
Question about Ricoh Aficio Office Equipment & Supplies
clear out error message 'replace fusing unit' ; nothing will print; can not get to maintenance menu because of error message You need to enter service mode, (this really should be done by a ricoh tech
...clear stop key more of 3 seconds. SC543 is a fuser over temperature error. A fusing temperature of over 231 degrees is detected for 5 seconds by the fusing thermistor: Fusing thermistor defective, ...