Indesit WA 125 Front Load Washer "pressure switch" Questions

Ad

Question about Whirlpool Washing Machines

1 Answer

...Pressure Switch from the Central Control Unit (CCU) or if the Pressure Switch contacts are not making, then "F32" is displayed. Possible Causes/Procedures: Pressure switch failure Check the Pressure ...

Ad

Question about Ariston Technologies Washing Machines

1 Answer

...Pressure Switch Empty and Full or neither Empty nor Full Pressure Switch Found Overhaul CN1 Overhaul Pressure Switch Wiring Control CN1/Pressure Switch Continuity Replace Pressure Switch Replace Card ...

Ad

Question about Ariston Technologies Washing Machines

1 Answer

Pressure Switch Empty found at the same time (Pressure Switch stuck on Empty) Overhaul CN1 Overhaul Pressure Switch Contacts Control CN1/Pressure Switch Continuity Replace Pressure Switch Replace Card

Question about Washing Machines

1 Answer

...pressure switch water level on the pressure switch is pre set make sure that nothing is in the pressure switch hose it connects from the pressure switch to the tub, if no obstruction then replace the ...

Question about Kenmore Washing Machines

1 Answer

...pressure switch has not tripped 8 minutes after the water valves are turned on and the flow meter has detected about 10.5 gallons of water entering the machine. Either the pressure switch contact is ...

...pressure switch on this model??? Service tech is looking to charge 80 dollars for part and 40 for labor. Hi. Replacing the water level pressure switch is not a difficult operation. Here guidelines. ...

Question about Indesit Washing Machines

1 Answer

...pressure switch hose. The pressure switch is located underneath the main top on the right hand side.The air dome is located on the back of the tub on the left hand side. If the pressure switch hose ...

Question about Zanussi Washing Machines

1 Answer

...pressure switch and level of anti-boiling pressure switch 2 (duration of fault at least 60 seconds). Cycle is blocked with door closed. Could be: Hydraulic circuit of pressure switches; ...

Question about Zanussi Washing Machines

1 Answer

...pressure switch and level of anti-boiling pressure switch 2 (duration of fault at least 60 seconds). Cycle is blocked with door closed. Could be: Hydraulic circuit of pressure switches; electronic ...

...pressure switch is open pressure switches in washing machines , control the water level in your case the program telling you the pressure switch did not operate when machine was filling or emptying , ...

Not finding what you are looking for?
Indesit WA 125 Front Load Washer Logo

148 questions posted

Ask a Question

Usually answered in minutes!

Top Indesit Washing Machines Experts