...If it is not working then you have to fix or replace it. The most rare but existing failure is call service 6000 due to defective power supply. In this case the heat roller is stuck on press
Question about Sharp Office Equipment & Supplies
...Heat Roller Temperature Detection. Possible causes: Thermistor abnormality Heater lamp abnormality Thermostat abnormality Control PWB abnormality Try resetting the error code using the following ...
Question about Kyocera FS Office Equipment & Supplies
...replace the fuser assembly. Try this before replacing the fuser.You do have to reset a new fuser also.Reset Fuser Life Using the control panel buttons scroll to Maintenance, press OK. Scroll to Check ...
...heat condition. Try this. May take a couple of times to clear. Press the in this order. Clear all ( yellow button) then press 107, then press and hold the red stop button until the screen changes to ...
Question about Ricoh Office Equipment & Supplies
...replace thermostat in heating section or u yuor tirmistor is directly touching the heat roller how do I clear error SC546 on a Ricoh Aficio 2045 SC546 A Fusing ready temperature unstable The fusing ...
Question about Kyocera FS Office Equipment & Supplies
...Press stop button for 3 second 4. copy sp 5. 5810# 6. Excute 7. Power off 8. Power on Please assist me to solve this problem. Alsadig Alnadif Darfur, Sudan If you've done all of those steps and the ...
Question about Sharp Office Equipment & Supplies
...it regards----best of luck Press C, Interrupt ,C, Interrupt - display off. Enter 14 Print. If it comes back , check the heater lamp continuity, thermostat and reset and thermistor clean or
replace periodically or in abnormal circumstance the heat lamp blew. This is a Service Tech reset code. You must go in service mode and then reset the SC/Jam in the service tables. To prevent this: 1.
Heat Error. Sometimes this code can be cleared by using the reset procedure outlined below. If the code returns then you will need to have the unit serviced. Reset Procedure: 1. Turn main power switch