20 Most Recent
Heath Zenith SL-6136-WH Basic Solutions Wireless Switch and Plug-in - Page 2 Questions & Answers
The light fixture stopped working.
Try installing a new switch if you haven't already. If you have make sure the wiring is correct and if all seems fine turn the breaker off and make sure its "hard" to reset, if not it's most likely the breaker... Unless you have a rat problem
I have a Heath Zenith
By pulling it apart and following the circuit path it should be fairly apparent how to 'bridge out' the faulty PIR sensor.
If it is not, or you are not sure, then (no offence), you really shouldn't be playing with it. Some units are transistor bypass and some are relay. Cheers
When door bell is pushed
The unit is receiving electricity so low-voltage transformer and button are working correctly.
Only suspect left is door chime itself.
Check that voltage of transformer matches voltage of chime.
Use cheap multimeter from home center and check voltage at chime, or check transformer.
Doorbell transformers are usually located in basement or garage or attic, and most are hardwired into octagon box.
There are no replacement parts for door chimes.
Buy new one, or contact seller for refund if this is new chime.
Can a neighbor motion light
Hello rob.... yes, your neighbor's light may well interfere with yours in that IF the neighbor's light is coming on first, your light will sense that it is daytime and it will not come on. These lights have sensitivity adjustments on them, generally, and the eye can often be redirected. A little experimentation may be necessary. Joe
Thanks for choosing Fixya!
Connecting a Heath Zenith Doorbell 172C-A
Do you have a transformer with it? Apparently this doorbell can operate on AC or DC (3-6VDC or 8-16VAC). The usual method is to supply 110 VAC to a transformer with an output of about 16VAC. ------ BE SURE YOU KNOW WHAT YOU ARE DOING WHEN DEALING WITH 110VAC. HAVE A CAPABLE ADULT HELP YOU WITH THIS! -------
Connect one of the two outputs from the transformer to one of the terminals on the bell (this might be labeled COMMON) The other output from the transformer will go to your handheld lead (like in the Operation game). Connect a lead from your patient (as in the Operations game) to a terminal on the bell which is probably labeled for AC.
Flood lights take a very long time to come on
Insure you are using a standard flood light on motion sensor lights and not a florescent energy efficient flood light as they take longer to reach full brightness as the bulb filiment warms up. They are better suited for constant lighting rather than intermittent purposes such as sensor lights.
Good Luck
My conlog meter is showing the rfcon error please what do I do
No connecting to your utilty company in South Africa. Just FYI, we are a North American site and my not always have the answer, in this case we do
Https://www.facebook.com/ConlogSolutions/posts/im-having-a-rf-con-error-cant-do-anything-on-the-gadget-please-help-on-how-to-re/962048393965724/
Quoting from link above: "
Conlog Hi Ola-daniels, Please see below steps to assist with RFCON error :
* Press the Back arrow on the keypad - this step is to refresh the UIU ( the device)
* Type # 75 # - this is to check the signal strength
If it does not go back to the normal display
*Type # 80 # - this is to refresh the meter
Then lastly you can repair the meter and the UIU by # 36 #
The above steps will work better if you are outside the house because the meters uses the radio frequency connection
The above error will occur in instances of bad weather conditions or if there is load shedding or power failure
If the problem persists after trying the above you may contact the municipality or the service provider."
SOLVED: How do I clear up the rf con error on my meter ...
https://www.fixya.com > ... > The
May 7, 2020 - How do I clear up the rf con error on my meter because I want to ... Https://www.facebook.com/ConlogSolutions/posts/im-having-a-rf-con-error- ... Hi Ola-daniels, Please see below steps to assist with RFCON error : ... shut down the energy alimentation for 2 minute ,but if the defect persist error it show again.
SOLVED: Pole meter conlog rf con meter keep on freezing ...
Jan. 10, 2017
Meter reading shows rF CON instead of units available - Fixya
Jun. 24, 2018
SOLVED: Good day my conlog ip54 elecricity meter showd ...
Oct. 6, 2018
SOLVED: Rf con error - Fixya
Jun. 20, 2020
More results from www.fixya.com
Please Help With My Conlog Prepaid Meter - Technology ...
https://www.nairaland.com > please-conlog-prepaid-meter
Aug. 6, 2020 - ystar: If the conlog meter is showing rf-Con, it means power supply doesn't reach the meter at all its either Loss of phase from the transformer or a loose contact ...
How Do I Load The Activation Token On My Conlog Prepaid ...
Mar. 17, 2020
I Need A Technician To Fix This... - Nairaland / General - Nigeria
Jul. 22, 2019
I Need Number Codes To Reset Memmcol Prepaid Meter ...
Jan. 11, 2019
More results from www.nairaland.com
Not finding what you are looking for?