Top 20
RTO Atwood DSI-RV Water Heater-6 Gallon Questions & Answers
Electronic burner lights then goes out in a few seconds
I am not sure about your particular heater but the thermocouple on a full-size gas water heater is often the cause of a pilot failing. It is relatively inexpensive to change (or mine was). It is a simple metal tube with a wire that is located near the pilot to tell the burner that it is ok to come on because the pilot is lit.
11/25/2013 6:28:21 PM •
RTO Atwood...
•
49 views • 0 helpful votes
My Atwood GC10A-3E will come on the first time I
Sounds like some adjustments are needed. Air shutter for one, and ignitor/electrode. Have you by chance observed outside with cover open when it tries to re-light? My guess is that it is sparking/trying to ignite, but adjustments are needed for proper ignition. A good cleaning of burner tube, electrode, and proper adjustment of electrode & air mixture should cure your problem.
9/10/2013 4:41:47 PM •
RTO Atwood...
•
290 views • 1 helpful votes
What Atwood water heater models will replace model GCH6A-9E?
Any 6 gal will fit in same cut-out (hole) . 12-5/8" H x 16-1/4" W x 17-5/8 deep. In order to move up to a 10 gal, you need to be able to cut hole a little bigger. 15-3/4" H x 16-1/4" W x 20-5/8" deep. Usually your depth will allow , and width is same, just a matter of whether you have room to make height bigger.
1/3/2013 2:23:35 PM •
RTO Atwood...
•
702 views • 0 helpful votes
Will not ignite
gas valve will not turn on if the blower is not pushing air thru the combustion camber. There is a sail switch in there that has to be working to complete the circuit back to the gas valve. BE CAREFUL and ck for a bee or wasp nest in the exhaust pipe or back in the combustion camber.
12/6/2012 12:00:59 AM •
RTO Atwood...
•
59 views • 0 helpful votes