Top 10 Sony FD Trinitron WEGA KV-32FS120 32" TV Questions & Answers

Sony FD Trinitron WEGA KV-32FS120 32" TV Logo

Question

  • 6,601 People Helped

Sony FD Trinitron WEGA KV 32FS120

Hi...I have a Sony FD Trinitron WEGA KV 32FS120 that is very difficult to turn on. When I try to power it on the stand by timer light blinks 9 times then stops the repeat for another 9 times. Aventunally the TV does come on after repeated pushs of the power button. Can some please tell it this something that I can repair or do I need a service person...Thank you in advance...David

Posted by on

Answer

  • Most Helpful of 14 Answers

This model does not have a G board. I will post when I have this solved.

Posted on Sep 23, 2007

Question

  • 6,114 People Helped

tv remote codes

need the code for the remote control for the sony tv kv-32fs120, i lost thepaper with the codes.

Posted by on

Answer

  • Most Helpful of 3 Answers

I have a Zenith universal remote that i want to program to a sony 27 inch Trinitron, what are the codes?

Posted on Nov 19, 2008

Question

  • 17,492 People Helped

Sony FD Trinitron WEGA KV-36HS500 blinking red light 6 times

Over the weekend my t.v. won't turn on it sounds like its going to but then the red blinking light keeps flashing 6 times. I have shut it down for 24-48 hours and still it won't turn on.

Posted by on

Answer

  • Most Helpful of 8 Answers

My Sony KV36HS500 Trinitron is doing the same thing. Last night the next street over was hit by lightning. The "7" blink pattern was happening, so like the manual stated, unplug it for 4 hours. Which I did. The t.v. is back up and running fine. It's a nice t.v., better than the plasma I paid over a grand for, that's already shot. It's a good t.v. and good that Sony put in the stand by protection to prevent the t.v. from dying an unnecessary young death. Patience, don't rush it, unplug the t.v. and leave it sit. Also, don't use a power strip, that was my mistake, and unplug your t.v. if storms are in the area, I was too lazy to and now I had to deal with this, in 8 years, only twice did this happen. I'd buy another one tomorrow if they still made them.

Posted on Jun 15, 2008

Question

  • 4,829 People Helped

4 blinks in standby/timer no picture

please help tv wont turn on

Posted by on

Answer

  • Most Helpful of 2 Answers

Here is a list of the problems that might have occurred indicated by the number of blinks. The words in parentheses are those, which you will see for each of these faults on a diagnosis screen described later in this article.

  • Unit is dead, No blinks - Problem in the standby power section. Might check fuse, R607, Q601, IC601, R612 and VDR601 (should show open).
  • Continuous blink once a second, no pausing - No reply from the jungle IC301 (data bus is busy, shorted to ground, or held high), IK video path is defective.
  • One blink - not used for the self-diagnosis
  • Two blinks - B+ over current protection (OCP), unit goes to the standby mode then displays the 2 blink fault. Could be a short in the power supply of any of the circuits.
  • Three blinks - B+ over voltage protection (OVP), unit goes to the standby mode then displays the 3 blink fault. This is also a problem in the power supply circuit, check T603 and R672.
  • Four blinks - No vertical Deflection (V STOP), Screen goes to a single horizontal line then the video signal muted. Check IC1509, Q1505
  • Five blinks - AKB circuit (automatic kine bias), the timer/standby indicator blinks for about 30 seconds then goes to the self-diagnosis function. Something is wrong with the video. Check video out, Q705, 732, 761 and other components on the C board, also check Q218, 219, 220 on the A board. In addition, unit could be in IK blanking, try turning up screen slightly.
  • Six blinks - No Horizontal (H STOP), no raster, goes to the blinking self-diagnosis function immediately. Check C515 & 516 and the jungle IC, IC206.
  • Seven blinks - High voltage shutdown. The high voltage has exceeded 33k and the unit goes immediately into safety shutdown. Check power supply regulation and horizontal circuits.
  • Eight blinks - Problem with the audio (AUDIO), unit goes to standby and blinks the self-diagnosis code. Check IC406 audio amp, PS401, and 402. On some projection models of Sony TV sets, this code means that T8005 (flyback transformer), or the associative components in the high voltage circuits are defective on the D board.

  • Nine blinks - Replace D 6116 and D 6301 on the "G" board, do not resolder as this will fix the problem temporary. Or Panel Module Error or Thermal Error. If it is intermittent 9 blinks, meaning sometimes the TV comes on and other times you get flashing, then change the switching regulator on the "G" board or check connections. Make sure the regulator is -12 or -13 (negitive).
  • Ten blinks - Check Q8014 and Q8013 for shorts, leakage, or bad solder connections on the " D" board. If the transistors are bad, check R8051 and IC8005, also on the "D" board.
Intermittent problems? This is a great feature. You can also bring up these fault codes on-screen to see a list of the problem numbers with the abbreviation of the problem and the number of times this problem has occurred. This is slightly different than entering the service mode. To see the diagnostic screen, press the following buttons: Display, Channel, 5, volume Minus, ( not plus ) then Power. This brings up a screen with a list of the problems and number of times they have occurred. Each of the problems named, are abbreviated as, "OCP", "OVP", "V STOP", ETC. We have repeated them in parentheses in the text for the "Blinks" described above so you can correlate between the diagnostic screen and the blink codes.
Now that you know about these self-diagnostics, how do you use them? Say that you have a set with a black screen. You see that the LED is blinking four times. This would tell you that you have no vertical sweep, which is why the video is muted. If it was blinking 6 times, you would know that you have a horizontal fault. It's not a sure cure..
IMPORTANT: After you repair the unit, you MUST clear the values on this diagnostic screen. These codes do not reset themselves after the fault is corrected, so if you don't clear them, you'll be seeing "old" fault codes the next time you enter this screen. Clearing is done by going into the service mode (display, channel, 5, volume plus, then power ). Press 8 and Enter,

Hope this may help;

Regards,
VOTIT

don't forget to rate

Posted on Aug 30, 2008

Question

  • 6,781 People Helped

My Sony Trinitron won't turn on...has 4 blinks in Standby.

My Sony Trinitron was working one minute....I put my TVR on pause and now my TV screen won't turn on...has 4 blinks in Standby. I've tried the hard reset..leaving it turned off for 5 hours..nothing. I understand according to previous articles about this that I'm supposed to "Check IC1509, Q1505" but what does that mean? How do I do that? Thanks for any help you can give. My Sony Trinitron wasnot working . TV screen won't turn on...has 4 blinks in Standby. I've tried the hard reset..leaving it turned off for 5 hours..nothing. I understand according to previous articles about this that I'm supposed to "Check IC1509, Q1505" but what does that mean? How do I do that? Thanks for any help you can give.
Comment by , posted on Sep 09, 2008 Thanks, Dan. I actually realize now that may model is different. Will that matter? My TV is a Sony Trinitron KV BM14M40.

Posted by on

Answer

  • Most Helpful of 1 Answers

Hello,
There are 3 reasons for 4 blinls
1.unit went to stand by mode because of h-pulse
2.Vertical defflection pulse stopped
3. power line is shhorted or power supply is stoped.

Solution:
1. check 13vdc on A board of powersupply stage
2. Check IC561 on A-board.

Good Luck
Dals123

Posted on Oct 15, 2008

Question

  • 7,841 People Helped

Sony Wega 40" TV will not turn on, standby light blinks 6 times repeatedly

I have a SONY FD Trinitron WEGA KV-40XBR800 TV that will not turn on with the power button. Sometimes it will turn on if you hit the power button and quickly hit the tv button,then it will turn on and work just fine, but this will not work all the time. When it will not turn on,the red standby light will blink 6 times continously. I would appreciate some help. THANKS, JOHN

Posted by on

Answer

  • Most Helpful of 2 Answers

Hello,For model KV-40XBR800,

Pls check following area.

Low HV Shutdown:
On the D Board.
Check IC8004/pin 7 should be 7.4v.
Check IC8006/pin 2 should be 2.5v if lower will trigger shutdown by causing pin 1 to turn on.
Check IC8006/pin 3 reference voltage 2.2v.
IC8006/pin 1 normally at 0v. If high
turns D5007 ON which turns the latch circuit Q6532,
Q6530, and Q6527 ON and turns the AC relay RY6501 OFF.

And NOTE: 6 blinks also can be Low B+ protection.

Unregulated 7.5 v from the power supply to 5v reg IC504 on the A Board. 5v to M Board Q2314

to CPU IC2300/pin 43. If 5v missing set will shutdown with 6 blinks.

Good Luck
Dals123

Posted on Oct 15, 2008

Question

  • 4,315 People Helped

Can't remove "video 1" from the screen

Can anyone tell me how to remove the "Video 1" from the screen. It used to appear for a time and then remove itself after a few seconds, now it stays on all of the time. The set is a Sony Wega 32"
Thanks for any help.

Posted by on

Answer

  • Most Helpful of 3 Answers

Usually, pressing the display button on the remote will cure this. You may also check in the set up menue for any display settings.
Hope this helps,
Skyassoc

Posted on Jun 17, 2009

Question

  • 15,143 People Helped

How can I reset a Sony Wega tv without a remote

How can I reset a Sony Wega tv without a remote control... I stand by button keeps on flashing and the tv wont stay on for more than 3 sec.

Posted by on

Answer

  • Most Helpful of 5 Answers

You can only reset the TV when you have the remote as it requires holding down the RESET button on the remote control, then pressing the POWER button on the TV front panel. The TV will turn itself off, then back on again. Then release the RESET button.
Regarding your problem with the TV not staying on for 3 seconds, you can try unplugging the unit for at least an hour to perform a hard reset of the microprocessor. If the unit still doesn't stay on, you need to check the power supply or the entire board for any blown or bad capacitor, shorted terminals due to accumulation of dirt, or broken solders. It may be a tedious task and requires an electronic prowess to do.
Kudos and thanks for using Fixya.

Posted on Nov 08, 2009

Question

  • 5,568 People Helped

My Sony Trinitron 32

My Sony Trinitron 32" WEGA Model KV-32FS120 does not turn on when the power button is pushed. The stand by timer light flashes 9 times, pauses, then flashes 9 times again and again. Any idea what the problem is?

Posted by on

Answer

  • Most Helpful of 4 Answers

Hi,
There is IC600 MCZ3001DB mounted on main board in power supply section, replace it. This will solve your problem.
MCZ3001DB is available in Part Store.
If you are handy with electronics stuff repair and can solder parts in circuit board then should attempt to repair TV by yourself and if you feel uncomfortable with working in TV, ask local tech to fix it.
Thanks.

Posted on Dec 21, 2009

Question

  • 5,680 People Helped

my sony trinitron tv wont

my sony trinitron tv wont turn on. it blinks 4 times on standby. what do i do

Posted by on

Answer

  • Most Helpful of 2 Answers

Try a reset:

  1. Turn on the television.
  2. On the TV remote control, press and hold either the RESET or UP ARROW button.
  3. While holding the RESET or UP ARROW button, press and release the POWER button on the front of the TV. NOTE: The TV will turn off and then back on.
  4. Release the RESET or UP ARROW button.
If that doesnt solve it, you will need a repair.

Posted on Aug 10, 2010

1,778 questions posted

Ask a Question

Usually answered in minutes!

Top Sony Televison & Video Experts

Grand Canyon Tech
Grand Canyon Tech

Level 3 Expert

3867 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

matt martin
matt martin

Level 3 Expert

1259 Answers

Are you a Sony Televison and Video Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

FD Trinitron WEGA KV-32FS120 32" TV Sony

  • FD Trinitron WEGA KV-32FS120 32" TV Sony

Most Popular Question

tv works vcr dut when sattelite box

  • Televison & Video
Loading...