Maytag MFI2568AES Stainless Steel Bottom Freezer French Door Refrigerator - Page 8 Questions & Answers
Programming hv board
I have the same Maytage MFI2568AEB on the inside top left of the refrigerator the code is 0302, i still cannot enter the code, showing PEO OOO.
9/23/2012 8:43:40 PM •
Maytag...
•
Answered
on Sep 23, 2012
Frozen code
did you change circuit board ???? youll need to reprogram the refig, there should be a paper that came with the new part( if indeed youdid cahngeit) if not there should be underthe right front corner of refig tapedup under behind the toe grill a tech sheet in which they should explain "programming your refrig"
9/23/2012 8:35:27 PM •
Maytag...
•
Answered
on Sep 23, 2012
Where does water go when it defrosts?
The water will go into a drain pan which is located at the bottom of the fridge. The hot discharge line from the compressor is in the drain pan which during normal operation will evaporate the water.
9/9/2012 5:48:52 PM •
Maytag...
•
Answered
on Sep 09, 2012
Mfi2067aes
First you need to verify the door switch is working properley and there is a power source there. After that you would be looking at faulty relays on the control board, and unfortunatey this means new board
Hoe this helps
9/9/2012 4:45:17 PM •
Maytag...
•
Answered
on Sep 09, 2012
Ge eterna touchpads
I would first pull the plug then reset the breaker then plug the unit back in. If the control panel does not come back on then check the power source by plugging a lamp or radio in where the fridge is plugged in. If they work the you will have to take the back panel off of the fridge and check for loose wires or a loose marrette. If all looks good then unfortunately it is probubally the control that is pooped out and needs to be replaced.
9/7/2012 3:50:43 PM •
Maytag...
•
Answered
on Sep 07, 2012
HV board problem. replaced board, but can not reprogram to enter new code. what do I do?
I recently had the identical problem after replacing the high voltage control board myself. Although display looked normal, no response to programming attempts. All I could think of was that the low voltage board under the display ppanel was also bad and was about to go out and buy it ($240 locally) when I ddecided to check its connections first. Took off the display panel, unplugged the 4 connectors, plugged them all back in. When I powered up the fridge, it responded to the programming directions and has been working normally except the ice-maker made one batch of ice and then just stopped. Now I have to try figuring that one out.
8/11/2012 11:22:12 PM •
Maytag...
•
Answered
on Aug 11, 2012
Programming code not working
Go to this web page to find the text answer below:
http://www.fixya.com/support/t233614-reprogram_hv_board
HERE TIS RIGHT OFF THE INSTRUCTION SHEET. THE TECH JUST LEFT. POWER UP REF. PROGRAM CODE IS LOCATED ON SERIAL PLATE ON THIS UNIT AFTER THE WORD CODE.-1. PRESS & HOLD THE DOOR ALARM KEYPAD.-2. PRESS & HOLD FREEZER TEMP DOWN KEYPAD.-3. RELEASE DOOR ALARM KEYPAD AND WAIT 3 :WILL DISPLAY PE TO INDICATE PROGRAMMING MODE-5. ENTRY IS CONFIRMED BY PRESSING TEMP DOWN - KEYPAD ONCE MORE.-CONTROL WILL DISPLAY CURRENT PROGRAM CODE. THIS VALUE SHOULD BE VALIDATED THE THE PROGRAM CODE PRINTED ON UNIT SERIAL PLATE.-NOTE: IF PROGRAM CODE IS CORRECT, THE PROGRAMMING MODE IS EXITED BY CLOSING THE FRIG DOOR.-7.PRESS REFRIG TEMP UP KEYPAD + OR REFRIG DOWN KEYPAD -TO CHANGE THE DIGIT VALUE WITH EACH KEY PRESS.-8.THE DECIMAL POINT INDICATES THE SELECTED DIGIT. PRESS THE FREEZER TEMP UP KEYPAD + TO SELECT NEXT DIGIT.-9.ONCE DEIRED PROGRAM CODE IS DISPLAYED, PRESS AND HOLD THE FREZZER TEMP DOWN KEYPAD - UNTIL UNIT PROGRAM CODE BEGINS FLASHING INDICATING IT HAS BEEN SAVED. *note* IF YOU ATTEMPT TO ENTER AN INVALID PROGRAM CODE, THE CONTROL WILL NOT SAVE THE NEW CODE, BUT WILL BEEP! (THE UNIT WILL NOT RUN RUN WITH A UNIT PROGRAM CODE OF 0000). ONCE THE PROGRAM CODE HAS BEEN SAVED THE PROGRAMMING MODE IS EXITED BY CLOSING THE FRIG DOORS.
7/30/2012 6:05:04 PM •
Maytag...
•
Answered
on Jul 30, 2012