Hi , HF is no water detected.
Parts that can give HF are: inlet valve, water supply, pressure switch and timer board (CCU).
Start doing procedure below:
No water detected entering machine or Pressure switch trip not detected.
If after 30 seconds the control does not detect water entering machine and then valves will be turned off and the error code will be displayed.
Or
If the control has turned the water valves on and after 8 minutes the flow meter has detected 10.5 gallons of water passing through it, but has not detected the pressure switch trip, the valves will be turned off and the error code will flash.
Press PAUSE/CANCEL twice to clear the display.
If there is no water in the unit:
1. Make sure that both valves at the water source(s) are turned on all the way.
2. Check for plugged or kinked inlet hoses or plugged screens in the inlet valves
3. Verify inlet valve operation
If there is water in the unit:
1. Verify Drain pump operation
2. Pressure Switch Hose is in good condition and properly connected to Tub and Pressure switch
- Verify there is not a siphon problem
- Verify wire harness connections to:Inlet Valves, Pressure Switch, Drain Pump, Flow Meter, and Central Control Unit (CCU)
- Check all hoses for possible leaks
- Verify pressure switch operation
- Verify flow meter operation
- Verify CCU operation
If that does not work you may need to call a technician to test inlet valve and pressure switch. In that case you can ring the number listed on the owner manual to get in touch with a Whirlpool rep.
Regards.