Runs but shuts off automatac
check the oil, most of these have a low oil shut down. If it's full make sure it's sitting level while running. If it still shuts down and is full of oil and level, bypass the low oil shutoff and see if it stays running.
12/4/2012 12:59:25 AM •
Coleman...
•
Answered
on Dec 04, 2012
Can it run for 7 days without stopping?
Joe,If you ran your generator for 7 days, it would be running for 168 hours. You MUST stop the engine every 50 hours and replace the oil. Otherwise, you will trash the engine.
11/9/2012 1:29:51 PM •
Coleman...
•
Answered
on Nov 09, 2012
Gx270 starving for gas
Hi, a possible cause of fuel starvation, often overlooked, is the vent hole in the filler cap, i.e. try running with the cap removed, if this works , then the tank is not venting properly, another possible cause is The float needle in the carb chamber may be stuck in its seat,! and a sharp tap on the side of the carb with a screwdriver handle often will free it off