20 Most Recent
Coleman Powermate Powermate 5000W Generator - Page 10 Questions & Answers
PM0557523 7500 WATT Vertex Coleman missing
There are at least two AVRs for this generator. The original AVR has the diodes mounted on an external heat sink. The updated AVR has the diodes mounted directly on the circuit board. I have a schematic of the original model with the external diodes but it doesn't have the values or parts on the schematic. I will be more than happy to e-mail you a copy of what I have.
8/24/2012 11:45:21 PM •
Coleman...
•
Answered
on Aug 24, 2012
I have a coleman maxa 5000 generator no spark
first look at the oil level some generators have a low oil shut off then remove the front cover of the engine and unplug the small wire on the side of the coil then try to start it if you get spark back the its a wire problem if still no spark then the coil is bad
8/18/2012 2:18:00 AM •
Coleman...
•
Answered
on Aug 18, 2012
It's almost brand new but
the #1 enemy of generators or any outdoor power equipment. Old gas. It turns to gook that gunks up the works.
8/12/2012 6:47:02 PM •
Coleman...
•
Answered
on Aug 12, 2012
Not finding what you are looking for?