Generator sat unused 2 years. whatshould be done before using for long periods

Change the oil and you will probably have to rebuild the carb. If it has a starting battery, that will need to be replaced as well.
8/10/2014 11:27:55 PM • Coleman... • 224 views • 0 helpful votes
0helpful
1answer

Generator owners manual

Try going to the website.
8/14/2014 10:01:20 PM • Coleman... • 138 views • 0 helpful votes
0helpful
1answer

Only has 120 volts,can not get 240volts

the generator consists of 2 120volt windings that run in parallel for 120 volts and in series for 240, check the change over switch make sure a wire hasn't fallen off, if you have a multi meter check both coils have the same resistance
7/19/2014 10:57:44 AM • Coleman... • 250 views • 0 helpful votes
0helpful
2answers

NEED THE GAS TANK DRAIN GROMET FOR POWERMATE 185432-0606E1

Try Ebay or Google to find a replacement part.
8/3/2014 9:17:04 PM • Coleman... • 153 views • 0 helpful votes
0helpful
2answers

What size of spark plug for a colman 5500 generator?

any good lawnmower or car plug will work ,just gap @ 35
5/31/2014 4:17:36 AM • Coleman... • 906 views • 0 helpful votes
0helpful
1answer

No 120v/240 output @twistlock recptacle

The big box home supply centers carry these. match up the current rating and voltage rating on the generator, then buy the receptacle to match.
7/27/2014 1:08:26 AM • Coleman... • 96 views • 0 helpful votes
0helpful
1answer

What oil to use for a pm54-2000 generator

USE A 30 W OIL IN THE GENERATOR MOTOR ASLO DEPENDS ON THE WEATHER .O N COLDER DAYS USE A 10W30
6/20/2014 1:50:23 AM • Coleman... • 257 views • 0 helpful votes
1helpful
1answer

I have a oil leak on a coleman generator

Most likely at the output shaft of the motor. If you are handy, you might be able to replace the crankshaft seal yourself, but this will probably require you to seperate the generator from the motor, and remove the cover holding the seal. If the leak is small, it may be best to just keep adding oil. If you have to take it to be repaired, it may be more expensive than the unit is worth.
3/26/2014 5:42:39 PM • Coleman... • 1,996 views • 1 helpful votes
1helpful
1answer

Generator will not idle

Check that the choke isn't stuck...should be a small curved pin you slowly pull in and out. Check your manual for its location. If its stuck in one position that could be your problem. If you can't find your manual, do an online search; usually you can download one.
4/22/2014 8:11:39 PM • Coleman... • 171 views • 1 helpful votes
0helpful
1answer

I need a wiring diagram for my powermate 5700? Do to my dog chewing off the wires

you need 2 replace the dog...! (BEFORE THE WIRING job) ...that's a really tight spot they're in.... HE'LL SEE NEW WIRES AND SAY.... OH GOODY....I bet he'll like this ! that's what he gets for leaving me home alone ....i'll show HIM !
3/8/2014 7:28:15 PM • Coleman... • 305 views • 0 helpful votes
0helpful
1answer

Coleman Powermate full throttle

There may be a choke handle that should reduce the engine RPM. Otherwise contact the Coleman technical support department.
12/22/2013 5:08:13 PM • Coleman... • 485 views • 0 helpful votes
1helpful
1answer

How to flash a generator

Flashing is done by applying power from a battery via a diode momentarily to the slip rings or ABR field wires, note the polarity, and connection time 1-2 seconds. This is done when a unit has lost it's residual magnetism in the rotor laminates due to sitting for long periods.09a2964b-b365-4259-8872-4f0fc996930e.jpg
12/6/2013 9:12:57 PM • Coleman... • 458 views • 1 helpful votes
0helpful
1answer

No power comes from the ignitions switch when I try to start my AEG diesel AGN5000 generator

It sounds like there is a loose wire going to the switch, or the switch itsself is bad. Follow all the wires from the switch to where each one goes and make sure they are all tightly connected and that none of them are broken or chafed through. If there are no problems there, it is most likely that the switch is bad.
3/3/2014 12:28:41 PM • Coleman... • 34 views • 0 helpful votes
0helpful
1answer

Generator starts but then turns off and wont turn back on

Make sure the oil level is at capacity first, then turn off the generator power breaker bar that allows power to flow to the recepticals. The generator must be started with no amperage draw until warmed up. If this does not help, then there is a problem and likely the unit has been overloaded and needs servicing.
12/2/2013 4:22:51 PM • Coleman... • 165 views • 0 helpful votes
0helpful
1answer

Hi i have a Black max, Powermate Generator model

You have excessive arching on the rotor slip rings by the sound of it, if you clean them and it works well then 3 hours later same problem? What is the conditon of the brushes? Also I trust youa r enot cleaning polishing them with sanpaper etc, they have a very fine finish and should be polished with a super fine grit paper or stone, pref while turning the engine. Any scratches won't work
10/5/2013 11:40:30 PM • Coleman... • 700 views • 0 helpful votes
0helpful
2answers

Have coleman 5000w starts an runs fine for about 5

check the valve clearances that's a good place to start if it still has a spark once it has cut out
10/19/2013 8:33:05 PM • Coleman... • 452 views • 0 helpful votes
0helpful
1answer

Engine surges

Check for carb gum, mixture is too lean. Check for dirt in main jet
12/24/2013 3:45:59 AM • Coleman... • 72 views • 0 helpful votes
1helpful
1answer

Hi i have a Powermate model PM0496750, 6750 Black

I doubt its anything to do with brushes unless power system has shutdown incorporated, could ignition coil breaking down when it gets really hot or similar check the oil level cut out switch
10/5/2013 11:29:25 PM • Coleman... • 312 views • 1 helpful votes
0helpful
1answer

UST 5500 GENERARATOR. WHICH WAY IS THE CHOKE

im not sure but easy to check remove tube from filter to carb and check visualy, wilst oppertating it
10/14/2013 3:40:19 PM • Coleman... • 180 views • 0 helpful votes
0helpful
1answer

The 220 outlet is only putting out power on one

What brand of generator and KW? If you onlyone leg of the 22V it us not likely to be the voltage regulator aor rotor. Check to make sure that the voltage is checked right off the stator leads, where they feed the circuit breaker, and not on the load side of the circuit breaker, If you only have 120V on one of the 240V lines at that point, it is the stator winding. Renee advancd-power-technologies.com
11/2/2013 3:08:57 PM • Coleman... • 101 views • 0 helpful votes
Not finding what you are looking for?
Coleman Powermate Powermate 5000W Generator Logo

849 questions posted

Ask a Question

Usually answered in minutes!

Top Coleman Electrical Supplies Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

john h

Level 3 Expert

29494 Answers

Are you a Coleman Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Coleman Electrical Supplies

  • Coleman Electrical Supplies

Most Popular Question

our off witch broken fix

  • Electrical Supplies
Loading...