Sharper Image Ionic Breeze GP SI730 Air Purifier - Answered Questions & Fixed issues

0helpful
4answers

Ionic breeze is arcing inside unit

I have a sharper image ionic breeze hybrid gp that ran fine for years unitl it recently started sparking / arcing at the base of the grid blades and always in the same spot. I cleaned it several times but the sparking always came back and the unit went into either "drying grid" or "attention required" mode. The solution I found was to stand the removable grid in 2 inches of Pine-Sol cleaner 50/50 diluted with water for 24 hours then brush again with the cleaning brush and hot water. Presto! No more sparking.
5/16/2021 5:50:43 PM • Sharper Image... • Answered on May 16, 2021 • 1,928 views
0helpful
1answer

What does it mean when the cleaning light turns red?

It means that the unit needs to be cleaned.
8/7/2014 2:53:40 PM • Sharper Image... • Answered on Aug 07, 2014 • 200 views
0helpful
1answer

What does it mean when the cleaning light is red?

It means that the corona wires require cleaning in order for the ionic filtration to again begin working (it is not filtering when the light is on).
7/9/2014 9:04:41 PM • Sharper Image... • Answered on Jul 09, 2014 • 225 views
0helpful
1answer

No power is getting to model s1730 sharper image ionic breeze after taking it apart to replace light bulb. Is there a fuse in this model?

yes there is a fuse on the board located at the base of the unit...if that does not fix problem replace unit.. :) I’m happy to help further over the phone at https://www.6ya.com/expert/jovani_c02b023fe087f6cd
11/16/2015 4:45:11 AM • Sharper Image... • Answered on Nov 16, 2015 • 818 views
0helpful
1answer

Why does a red light on top of the ionic breeze GP S1750 blinks and does not blow the air

well i had the same problem at one time ..heres what to do... try turning it upside down and bang on the unit gently .not to break it and make sure you did not break the two strings behind the vents.. take out the bulb and clean the whole inside as best as you can.. and if that wont work unplug turn button to on pisitioin and then plug the unit inand hope for the best ... if all else fails go to amazon and replace the unit..hope that helps I’m happy to help further over the phone at https://www.6ya.com/expert/jovani_c02b023fe087f6cd
6/11/2014 4:17:18 PM • Sharper Image... • Answered on Jun 11, 2014 • 1,273 views
0helpful
1answer

Operating manual

You can go right to the Sharper Image site and get manuals there. Just find your model, and towards the bottom of the description you'll find links to the manuals, Try this one http://www.sharperimage.com/pdf/Electrostatic-Air-Purifierc.pdf
4/20/2014 5:00:16 PM • Sharper Image... • Answered on Apr 20, 2014 • 348 views
0helpful
1answer

I have a Sharper Image Ionic Breeze GP S1730 the

One person used piano wire, but the diameter must be right so the cleaning beads can slide up and down on the wire when the unit is turned up and down.
12/4/2013 9:28:03 PM • Sharper Image... • Answered on Dec 04, 2013 • 685 views
0helpful
1answer

Red light comes on after cleaning S1730 GP Sharper Image

Make sure filter is positioned correctly and fully seated.If it does not come on with a clean dry filter it may be a faulty high voltage component.
2/6/2012 5:31:35 PM • Sharper Image... • Answered on Feb 06, 2012 • 589 views
0helpful
1answer

Light blinks on and off.inside light turned off.

Clean metal fins and make sure there is no moisture on metal fins....let it air dry after using towels to remove all moisture on fins, then replace into body of ionic breeze.
11/23/2011 11:51:34 AM • Sharper Image... • Answered on Nov 23, 2011 • 197 views
0helpful
1answer

I have the sharper image

http://www.consumeraffairs.com/retail/sharper_image.html
There have been major problems with these it seems check link above... It looks like it is a makers fault? They have gone bankrupt it appears. There is no fix i seems sorry to say.
8/20/2011 2:16:57 AM • Sharper Image... • Answered on Aug 20, 2011 • 87 views
0helpful
2answers

BULB AND BLUE BLINKING LIGHT S1871 AND S1861

Hi there,

What is happening is this: the main electrical component is overheating and forcing the machine to turn off. When it cools, the machine turns back on. Yes, that is actually what is causing the blinking.

There is no solution for this as the main electrical component (a high voltage capacitor in this case) has failed due to stress. In my case, the machine worked for 2 months before failing. The only real solution is to have the unit serviced. However, as there is no service centers, we are all out of luck.

I believe this could be a class action law suit against sharper image for selling units built with components it knew would fail after a short period of time. They had hundreds of reports with this same failure and they knew the cause. Pressing the "boost" button too much causes extreme stress on the capacitor and shortens its life drastically. This capacitor is what provides the power to the ionizing wires.

Good Luck!!!

neo
6/8/2011 12:18:59 PM • Sharper Image... • Answered on Jun 08, 2011 • 467 views
0helpful
1answer

Broken wire inside ionic breeze

Hi, actually the broken wire is nichrome and measures approx .00045 inch. Go buy a couple of .09 guitar strings from your local music store and use to replace it.....
10/21/2012 9:42:51 PM • Sharper Image... • Answered on Oct 21, 2012 • 1,933 views
0helpful
1answer

Operating instructions what do the

First of all, here is the direct link to the ONLINE USER'S MANUAL for that model:

http://www.ionic-air.biz/sharper-image/Ionic_breeze_gp.pdf


To view the Owner's Manual with Operating Instructions just use your mouse to click on the link, which is the underlined and highlighted text just above. This will open a new web browser page automatically for you and allow you to view the information at the website indicated or the contents of the Owner's Manual.

You may need ADOBE READER installed on your computer to read PDF documents. You can download this free at WWW.ADOBE.COM if necessary. Click on the DOWNLOAD ADOBE READER button on right side of the ADOBE home page when you get there.

The lights are ultraviolet lamps used to kill germs in the airflow. See page 4 and 11 of the manual for some additional details and safety precautions.

Please comment back here to this page if you have any questions, have difficulty accessing the links, or just require further general assistance and I will respond as soon as I see it.

Thank you very much and good luck.

Joe.
3/26/2011 5:35:23 PM • Sharper Image... • Answered on Mar 26, 2011 • 658 views
0helpful
1answer

Who could I send the

If you purchased it before 2008, nobody. Sharper image went bankrupt and was bought by another co who does NOT warranty or repair older products. Below is excerpt from their site:

Q. I bought an item from the Former Sharper Image that is broken, what do I do?
A. Unfortunately, we are not able to assist you with products purchased from the Former Sharper Image Company, which filed for bankruptcy on February 19, 2008. We are a new company offering new and innovative Sharper Image products.

Q. What happened to the Sharper Image retail stores?
A. All Sharper Image retail stores have closed.

Q. What is the difference between the New Sharper Image and the Former Sharper Image?
A. On Friday, May 30, 2008, the Former Sharper Image (The Sharper Image Corporated) assets were acquired by a joint venture formed between Hilco Consumer Capital, Gordon Brothers and Bluestar Alliance. This joint venture has been re-established as The Sharper Image. Through a licensing agreement with The Sharper Image, Camelot Venture Group, is in charge of managing and operating the SharperImage.com website and ecommerce platform. SharperImage.com has no affiliation to The Sharper Image Corporated ("TSIC") that filed for bankruptcy in 2008, or any of the various retail stores currently selling Sharper Image licensed products.

3/7/2011 6:13:34 PM • Sharper Image... • Answered on Mar 07, 2011 • 489 views
0helpful
1answer

I need a replacement sylvania

Try this site: http://www.replacementlightbulbs.com/lampg6t5.html .

I hope this helps.

Cindy Wells
3/2/2011 2:04:59 AM • Sharper Image... • Answered on Mar 02, 2011 • 303 views
0helpful
2answers

Ionic Breeze GP S1830 - makes a sizzeling noise

Funny you should post this when you did as I just finished reassembling my S1730.
Mine was making very loud noise, arcing violently, smoking slightly and would give a good shock when you touched the plastic covers(yes dirty plastic will conduct electric current).

1. Unplug the unit
2. Take the plastic covers off, front has four screws and back has snap at bottom, both slide up when loose.
3. Wash the plastic covers
4. take the light out and clean it with windex
5. Vacuum the inside, be careful of the two corona wires
6. Find the bead on each corona wire and while turning them slight so the edges scrapes the wire, move them back and forth to scrap the white power off the wires
7. scrape the cone shape plastic that the corona wires runs into, this build up is the primary culprit of the arcing which is the noise you hear. be careful of the corona wires again. I used an exacto knife and gently scraped it, sandpaper has been suggested elsewhere, once done scrapping, wipe down to clean any residue. The top cones are only part accessible, after cleaning mine the noise still persisted but acceptably lower than before. I think if you completely take apart the unit you can clean this cones better.
8. Reassembly is the same is opposite of disassembling.

Hopes this helps you.
1/23/2011 3:41:37 PM • Sharper Image... • Answered on Jan 23, 2011 • 2,347 views
0helpful
1answer

I have model S1730, is

I have replaced those wires with chrome plated wire, stainless steel wires and platinum wires. Nothing lasts very long (weeks to a few months). There are no parts available for these machines as far as I know.

Charlie
6/15/2014 3:54:38 AM • Sharper Image... • Answered on Jun 15, 2014 • 722 views
0helpful
1answer

How big of an area

The unit will clean from 500 to 600 sq. ft.
12/16/2010 10:49:04 PM • Sharper Image... • Answered on Dec 16, 2010 • 53 views
0helpful
1answer

Ionic breeze gp just stopped working

Hi.

I don't know if you are still trying to repair the air purifier.

About your Ionic breeze purifier, I wanted to report that they are not being manufactured anymore because of heath concerns. New model built from 2008 use a completely different technology. Parts are also not distributed anymore, and the new Sharper Image does not provide any support for the old model.
I suggest replacing the ionic purifier with a different air purifier.

Please read the article below:

Ionic Breeze Health Concerns

Regards.

Ginko.
10/1/2010 9:07:06 AM • Sharper Image... • Answered on Oct 01, 2010 • 940 views
0helpful
1answer

I need 2 new UV-C

Hi.

Both Ionic Breeze purifier and replacement parts had been retired from the market because of health concerns related to ionic technology. Parts are sometimes available on ebay, but I suggest not carrying any repair on this unit.

Please read the brief article that I wrote here: http://www.fixya.com/support/r5303535-ionic_breeze_parts_repair
9/13/2010 12:16:52 PM • Sharper Image... • Answered on Sep 13, 2010 • 329 views
Not finding what you are looking for?
Sharper Image Ionic Breeze GP SI730 Air Purifier Logo

148 questions posted

Ask a Question

Usually answered in minutes!

Top Sharper Image Air Purifiers Experts

Cindy Wells

Level 3 Expert

6688 Answers

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Are you a Sharper Image Air Purifier Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...