Froze up now won't cool
turn system off or leave the fan only on and thaw system out, when it is dry, check filter, if not the problem more than likely it was turned down to low or the freon charge is low and should be check by technician.
Aircon wont turn on
well check ur batteries in ur remote control unit and replace them with new ones instruction to do this u will find in ur user guide......
Manuals
you would have more luck throwing that remote away and buying a universal one for it
Please help i got a LG r12awn split and the
Indoor Pipe Sensor or Outdoor Sensor Assy fault, Open or Short. Disconnect from PCB and measure resistance. Air sensor = 10 kOhm at 25C, Pipe sensor = 5
kOhm at 25C. If not replace sensor. Thanks.