Firmware update error: An error message appears when either of the following Main PC boards is installed to e- STUDIO223/243. - The Main PC board for e-STUDIO181/211 - The Main PC board for e-STUDIO163/166/203/206
Causes
Remedy
Check the MAIN board. A C94 error message appears when either of the following Main PC boards is installed to e-STUDIO223/243. • The Main PC board for e-STUDIO181/211. • The Main PC board for e-STUDIO163/166/203/206.
Does the CIS case move to its home position when the power is turned ON? If YES, check the CIS home position sensor follow by MAIN board. If NO, check SCAN motor.
×