Firstly, the fuse is just a slow blow 1 Amp short style. You should be able to get an equivalent at any electronics parts supplier (a 1.25-1.5 Amp will do as long as it is the correct physical size).
Secondly, the cause of it blowing the mains fuse is probably a short in the primary winding of the Toroidal transformer. I have now replaced the transformer in mine twice over about 4 years.
If you cannot get the original Toroidal transformer (with the correct connectors) use a 50 or 80VA 12+12V Toroidal Transformer and connect the secondary windings in series. You should be able to get one for AU$30 to AU$40.