The 929 fatal error
Waste Toner
Transfer Motor
Lock Error.
The waste toner transfer motor is not operating properly. Does the error still occur? Yes
Check to confirm that the waste toner transfer system is operating properly.
Replace the waste toner motor.
I had error 929 on my Xante. It root of the problem was toner jammed up inside the the transfer belt. I replaced the transfer belt and the problem was eliminated. If you don't have a spare on hand you can try taking it apart and vacuuming out the toner.
this error most of the times is the transfer belt. After you change it it should work ok.
×
SOURCE: Xante Ilumina 512 error code
this error can be caused by a new or existing PC on your network. EXAMPLE: the network settings on new DELL pc's are default set to control the network and repair any conflicts..it seems dells dont like Ilumina's, and they get this error code.
Disable the network control function in the DELL settings.
And this error will not re appear until another dell is installed.
SOURCE: Xanté Ilumina: 020 fatal error
unplug power. open rear panel (2 thumb screws) check fitting of the ROM chips, restart..
020 relates to Slot A ROM DIMM
May need new ROM, or that CU PCB if unsuccesful
SOURCE: please what can I do
If you are in a Windows OS it means that:
133 JOIN or SUBST command can not be used for a drive that already contains readers joints.
So uninstall your printer and install it again using the best driver.
2,086 views