Pls help me out in solving error261
E261
0000 The intervals of zero-cross signals deviate from the tolerance range while
the fixing heater is supplied with power.
Main cause The wiring is faulty (short circuit, open circuit). The main power supply
PCB is faulty. The DC controller PCB is faulty.
Making Corrections
1. Connectors
Are the connector J205 on the main power supply PCB and the connector
J308B on the DC controller PCB securely connected? (zero-cross signal:
J205-7 <-> J308B-1)
NO: Connect the connectors securely.
2. Main power supply PCB, Main controller PCB
Try replacing the main power supply PCB. Is the problem corrected?
YES: End.
NO: Replace the DC controller PCB.
223 views
Usually answered in minutes!
hello sir i want to ask i have problem for e261 canon ir 2018 i solve the problem i change power suply its working but the main thing is i want to prepare the powersupply boad but the main purpose is i want a circuit diagram for canon ir 2018 any want to help me
×