Kenmore 52542101 was working fine all the sudden quit cooling. Unplugged it over night then plugged it back in, now the compressor kicks in for about 3 seconds then back out. Is it low on coolant?
No the PTC relay on the compressor is bad. Need to replace it.
First be sure to unplug frig. Remove the cardboard cover that covers
most backs of the frig units. Remove the plastic cover that is on the
side of compressor. It is held on with a metal clip. Now you should be
able to see the relay pry the relay straight off. note the wiring and
position of relay. Only three prongs on compressor. Go to a parts house
for appliance's and with your make and model number should be able to
get a new one. Let me know if you need any more help. ken
450 views
Usually answered in minutes!
Thank you so very much Ken!!! This was the correct problem, I went to local company and got the relay and it is working like a charm!!! Thanks your a lifesaver!!!
×