Code
C5102
Description
Main motor malfunction
- The main motor (M1) lock signal remains HIGH for a continuous 1-sec. a period at any time 1 sec. after the main motor has started turning.
Remedy
1 Check the connector between M1-PRCB CN6 for proper connection and correct as necessary.
2 Check M1 for correct drive coupling and correct as necessary.
3 M1 operation check.
4 Change PRCB.
5 Change DCPU.
I’m happy to assist further over the phone at https://www.6ya.com/expert/latoya_8ed1bf3dc615c15d
SOURCE: We have an error message
C5102 means that your main drive motor is not turning when it should. This could be as simple as a loose power connection on the motor but that would be very un-likely. Most often this code is caused by something in the machine that is turned by the main drive motor has beccome stuck or has "frozen". This causes the motor to not be able to turn as it should. If turning the machine off then back on does not reset the code and restore the machine to operating condition then you will need a service technician to come out and determine was part has locked up.
Good Luck and Thank You for using Fixya.
WheatlandServices
SOURCE: I have a Konica Minolta Bizhub c252 what is code c-5102
C-5102/5103 - Main motor failure.
Check the motor connector,the drive coupling or the mechanical control board and DC power supply unit.90% mechanical rpoblem.