Ahh, there it is!!! Hold down [PARAM] + [TRIGGER] and Power Up. [Memory Up] to "10". [RECALL] Cycle PowerAhh, there it is!!! Hold down [PARAM] + [TRIGGER] and Power Up. [Memory Up] to "10". [RECALL] Cycle Power
Why won't this site let me post this as a solution (faded out), and why did it "butcher" my first comment? Sheese, shouldn't be this difficult to answer you own question!!Why won't this site let me post this as a solution (faded out), and why did it "butcher" my first comment? Sheese, shouldn't be this difficult to answer you own question!!
This worked for the SPX900 as well! Be careful! It doesn't show you that it "did" anything...just cycle power...This worked for the SPX900 as well! Be careful! It doesn't show you that it "did" anything...just cycle power...
You can't post conmments that contain an email address.
- If you need clarification, ask it in the comment box above.
- Better answers use proper spelling and grammar.
- Provide details, support with references or personal experience.
Tell us some more! Your answer needs to include more details to help people.You can't post answers that contain an email address.Please enter a valid email address.The email address entered is already associated to an account.Login to postPlease use English characters only.
Tip: The max point reward for answering a question is 15.
https://www.manualslib.com > ... > Reference manual
This function lets you restore the status of the instrument to the original factory settings. ... buttons to enter or remove the checkmark. ... operation for all ...
To reinitialize the IS-SPX-1000 unit to its factory default settings:
1.
Unplug the unit from the power.
2.
Push the reset button and keep it pressed.
3.
Power up the IS-SPX-1000 unit.
4.
Wait with the reset button pressed for at least 8 seconds.
5.
Release the reset button.
6.
The IS-SPX-1000 unit will now boot in the factory default mode.
Hi
The normal reset is to hold down the highest note ( furtherst white key to the right ) at the same time as turning the instrument on. This will initiate a factory reset.
Ahh, there it is!!!
and Power Up.
to "10".
Hold down +
Cycle Power
Ahh, there it is!!! Hold down + and Power Up. to "10". Cycle Power