After a power utage, the fridge stopped cooling. the freezer freezes, but fridge does not go below 50 degrees.
SOURCE: Roper RT18SKXRD01 refrigerator not cooling
Hi: When this happens it means that there is frost built up in the back of the refrigerator. You are having an issue with the defrost heater or the defrost timer. There is an off chance the refrigerator's freezer is over packed with food and there is no circulation. If you're handy empty the fridge and take a hair dryer to the back wall to melt away the frost from behind. You will have to remove the back metal wall. Look at the heater. It will be at the bottom of the freezer behind the back wall. A glass tube with a wire coil running through it. If the coil is broken, replace it. If not you will be looking at a defrost timer. Sometimes on a circuit board. Searspartsdirect will have the parts and schematics. I hope this helps, Jeff
SOURCE: Does not hold temperature, warms up.
if you hauled on its side then it is very possible you have oil in evaporator. replace all sealed system parts. compressor, drier and evaporator.
SOURCE: refrigerator hardly cold freezer not freezing
Hi,
Many times a freezer and/or refrigeratordo not work right because of a dirty condenser coil...there are also many otherthings that can go wrong.
If you are hearing a clicking or buzzing then check out thelast two tips.
If your refrigerator is running but warm, then...
Check out this tip that I wrote about that... it is a great place to starttrouble shooting your unit...and something that you can do rather then callinga repair person to do a simple thing for you...
Refrigerator Condenser Coil Cleaning Refrigerator Repair
Refrigerator Troubleshooting Refrigerator Compressor
Refrigerator Compressor Start Capacitor and Start Relay
Refrigerator or Freezer not Cooling or Getting Cold
heatman101
SOURCE: Roper RT18DKX FW04. Freezer is
You have a DEFROST PROBLEM
The evaporator coil behind the cover on the back wall inside the freezer will ice up under normal conditions. Every 8 to 10 hours for around 20 minutes the defrost timer (or in most newer models the electronic adaptive defrost control) will turn the defrost heater on to melt the built up ice. There is a defrost thermostat which prevents the heater from overheating the freezer by breaking the heater circuit when the temp reaches close to 32 degrees F. The entire cooling system shuts off during the defrost cycle and starts back when the timer advances through the cycle.
If this ice is not melted it will continue to build up until the air can't flow over the coil to circulate the cold air through the freezer and into the fridge. The temperature change in the fridge is usually noticed first followed by the freezer.
If the defrost thermostat is bad, it can prevent the heater from coming on OR it won't turn the heater off when it gets too warm. It is clamped to the evaporator coil at the top to sense the temp. If it appears to be misshapen it is bad.
With an ohm meter it should show continuity when cold and none when warm.
You can also bypass(disconnect the two wires plugged into it and twist them together) the thermostat to see if the heater comes on then. If it does then you know the thermostat is bad and needs replaced.
The defrost heater is located on the evaporator. It is in a tube which is at the bottom and can also go up the sides of the evaporator. On some types you can see a burnt spot if it's bad. With an ohm meter it should show continuity from end to end when disconnected from the wiring in the freezer. You can also test the wiring for voltage when it's in the defrost mode.
If you have a defrost timer you can test it. It can be located under the fridge behind the kick panel on the front. Some are in the fridge with the controls at the top. You can turn the defrost timer till it clicks and everything shuts down. The heater should now come on. If it does, replace the timer because that means the timer is not running. If it doesn't, check the heater and defrost thermostat. Turn the timer again till everything starts back up to end the defrost cycle.
If you have an adaptive defrost control instead of a timer, replace it if the heater and thermostat test good. It is located in the fridge with the controls in some models and on the back in others.
Hi,
Check out these tips...they can help you figure out what is going wrong with your refrigerator and why it is not cooling
Refrigerator not Cooling or Fridge not Cooling
How to Defrost Refrigerator Defrost Timer Problem
Water Running in refrigerator from Freezer
Refrigerator or Freezer not Cooling or Getting Cold