The code is 163. Of course you will need to enter maintenance mode first, it is 10871087, once you have changed the value of 163 and save it, you can exit the maintenance mode by entering 001 and pressing the OK key, or just powering off and back on. If the reset does not work, replace the fuser. Dealers do not replace parts in these fusers, but if you decide to fix it, you should replace the thermocouple and thermistors.The code is 163. Of course you will need to enter maintenance mode first, it is 10871087, once you have changed the value of 163 and save it, you can exit the maintenance mode by entering 001 and pressing the OK key, or just powering off and back on. If the reset does not work, replace the fuser. Dealers do not replace parts in these fusers, but if you decide to fix it, you should replace the thermocouple and thermistors.
You can't post conmments that contain an email address.
First you must get into the service mode by keying in 10871087
The screen will start blinking - then key 163 and the screen should read cancel or execute -select execute
when it is complete turn unit off then back on and see if that worked, if not buy a new fuser unit. They cost around $150,00 to $200.00 depending on who you buy it from.
- If you need clarification, ask it in the comment box above.
- Better answers use proper spelling and grammar.
- Provide details, support with references or personal experience.
Tell us some more! Your answer needs to include more details to help people.You can't post answers that contain an email address.Please enter a valid email address.The email address entered is already associated to an account.Login to postPlease use English characters only.
Tip: The max point reward for answering a question is 15.
It is a fixing assembly error code. The thermistor doesn't detect heat. Kyocera you replace the fixing assembly. You may be able to reset.1087 1087 gets u into served mode go to reset and activate.power off and on.
This Code means low fixing unit temperature. If the power goes off and on, or Suzy Sec. has a space heater on the same circuit, this could be a false code.
Enter the service mode by keying in the numbers "10871087", on the key pad. enter the number 906, press start, press "execute"on the touch panel. The machine will reboot.
If the code comes back, you either have a bad thermistor, thermostat, or heater lamp. I have only had to replace the thermistor. The Fuser comes in the maint. kit ,so I always have some old ones laying around.
how can i reset error code c6050 in my photocopier km 1500
The code is 163. Of course you will need to enter maintenance mode first, it is 10871087, once you have changed the value of 163 and save it, you can exit the maintenance mode by entering 001 and pressing the OK key, or just powering off and back on. If the reset does not work, replace the fuser. Dealers do not replace parts in these fusers, but if you decide to fix it, you should replace the thermocouple and thermistors.
×