Washing Machines Logo

Related Topics:

A
Anonymous Posted on Apr 24, 2014

WHAT IS F12 IN A WASHING MASHINE ARISTON AQUALTIS AQXXF 129 H?HOW CAN I FIX IT?

1 Answer

Dado

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Master:

An expert who has achieved Level 3.

  • Ariston Tech... Master 511 Answers
  • Posted on Oct 06, 2015
Dado
Ariston Tech... Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Master:

An expert who has achieved Level 3.

Joined: Aug 05, 2011
Answers
511
Questions
0
Helped
482732
Points
1313

F12 SPECIFIC FOR LVB2000 INDESIT EVOLUTION / DIALOGIC.
F12: Lack of Display card-Main Card Communication
1. Check the effectiveness of contacts on CNC Connector Card
2. Overhaul 8-way connector on Display card
3. Check continuity of CNC-CN 8 way connector
4. Replace Main Card
5. Replace Display Card

Dado

1 Related Answer

ercupa190

ernesto cuadra

  • 12223 Answers
  • Posted on Sep 30, 2012

SOURCE: Ariston AQXXF 129 Error code F 05 - What is this?

see this causes and fix it. God bless you
F05 Water temperature sensor error If during the water heating step in the wash cycle, the water temperature sensor (NTC) value is out of range, or the heating element circuit has failed, the F05 error code will be displayed.

Potential Causes

• Check the Water Temperature Sensor, Heating Element and Element Relay
• Check connections to the Sensor, Heating Element and Relay

Replace failed component.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Aquatis AQXXF 129 h. what is the error code 08?

It means "heater relay cannot be activated". Troubleshooting guide says to tap the relays to try to unjam them. If that fails, replacement of the main control board is necessary. These washers apparently have a propensity for stuck relays on the newer units.
0helpful
1answer

How to change noisy bearing on Ariston AQXXF 129

inner and outer drum has to b removed replace the bearing kit 2 bearings one oil seal as kit
0helpful
1answer

Lavadora aqualtis error11

F11: Pump Feedback Missing
Overhaul CN1
Overhaul CNF
Overhaul Pump Connector
Overhaul Pressure Switch Connector
Control Pump Windings
Replace Pump
Replace Card

Dado
0helpful
1answer

Lavadora secadora ariston aqualtis aqm8d error f13

F13: NTC wiring harness disconnected from the dryer system
1. Check the efficiency of the terminals on the CNA connector board
2. Check NTC wiring harness
3. Check the wiring harness continuity of the CNA / NTC connectors
4. Replace NTC
5. Replace terminal board

Dado
0helpful
1answer

Aqxxf 129 What has to be done to correct an f-08 error?

F08 - Heater relay cannot be activated

  • Check wiring
  • Check pressure switch and connections
  • Tap relays as they can jam on new boards
  • Check electronic control PCB
  • Check heating element

Dado
1helpful
2answers
0helpful
1answer

Ariston AQXXF 129 Error code F 05 - What is this?

see this causes and fix it. God bless you
F05 Water temperature sensor error If during the water heating step in the wash cycle, the water temperature sensor (NTC) value is out of range, or the heating element circuit has failed, the F05 error code will be displayed.

Potential Causes

• Check the Water Temperature Sensor, Heating Element and Element Relay
• Check connections to the Sensor, Heating Element and Relay

Replace failed component.
19helpful
4answers
2helpful
1answer

Error code 07 on my Aqualtis AQXXF

Might be a bit complex but this is your problem and solution

REMEMBER TURN THE POWER OFF

F07: Heater relay stuck or element open circuit
This fault is only signalled when pressure switch is in empty position.
Check the efficiency of edge connector J3 on module.
Check wiring to heater and continuity of element (25 ohms approximately).
Check the efficiency of pressure switch connections and correct operation of pressure switch,
and the pressure chamber is not blocked with sludge.
Remove edge connector J3 and check wiring and contacts at positions 2, 3 and 4 on J3.
If all above OK replace pressure switch, module or eeprom as required.
Not finding what you are looking for?

582 views

Ask a Question

Usually answered in minutes!

Top Ariston Technologies Washing Machines Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

vince

Level 3 Expert

2530 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66847 Answers

Are you an Ariston Technologies Washing Machine Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...