Electrolux EIMED55IIW 8-0 cu- ft- Electric Steam Dryer - IQ-Touch Cont Logo
A
Anonymous Posted on May 18, 2014

Countdown timer not working

The timer showing how much time is remaining is stuck on the initial time. It will not show how much time is left in the dry cycle. Dryer is less than 1 year old.

1 Answer

  • Official Brand Answer 4,342 Answers
  • Posted on May 21, 2014
Electrolux
Official Brand Answer
Level 0:

Joined: Mar 24, 2011
Answers
4342
Questions
0
Helped
1467895
Points
5907

Good Afternoon Friend,

I understand that the timer on your Electrolux dryer, model#EIMED55IIW, is not advancing to show you how much time is left on the dry cycle. I suggest resetting your appliance, by either unplugging it or shutting the power off at your homes circuit breaker, for 3-5 minutes. Restore power and restart your dryer. I ask that you please follow up with a comment on the post, at your convenience, to advise if further troubleshooting is needed or if your dryer status has changed successfully.

-Best Regards-
WP

1 Related Answer

Anonymous

  • 4 Answers
  • Posted on Feb 05, 2011

SOURCE: I have an e63 error

try cleaning out the lint in you vents. Its your dryer getting too hot. u will need to replace the heater tube it this doesn't work

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

How do I set the time on a KADIO KD-3806 digital clock

Earlier FIXYA question:

sachin_arane


  • Contributor
  • 2 Answers
ALL PARAMETERS CAN BE ADJUSTED BY USING KEYS

GIVEN BACKSIDE...KEYS ARE

MODE (LONG PRESS-4 SEC) TO ENTER INTO SETTINGS;

UP/DOWN TO CHANGE THE PARAMETERS; \

*C/*F KEY TO TOGGLE BETWEEN TO TEMPERATURE FORMAT;

SNOOZE BUTTON TO SET SNOOZE IN ALARM-MULTIPLE SNOOZE CAN BE SET;

RESET KEY CAN BE USED TO RESET CLOCK TO DEFAULT;

DAY COUNTDOWN , AND TIME COUNTDOWN CAN BE ADJUSTED;

DETAILED INFORMATION TO SET THE CLOCK

INSERT CELLS;-SCREEN SHOWS DEFAULT VALUES-INITIAL MUSIC WILL RING;
LONG PRESS MODE BUTTON-KEEP IT PRESSED UNTIL 12 STARTS BLINKING;
USE UP /DOWN BUTTON TO ADJUST HOURS...
THEN SIMPLY PRESS MODE AGAIN, NOW MINUTES 00 IS DEFAULT WILL START BLINKING;
USE UP/DOWN BUTTON TO ADJUST MINUTES;
AGAIN PRESS MODE, SCREEN WILL SHOW YEAR 2002 DEFAULT BLINKING, USE UP/DOWN KEY TO ADJUST YEAR;
AGAIN PRESS MODE, SCREEN WILL SHOW MONTH BLINKING, USE UP/DOWN KEY TO ADJUST CURRENT MONTH;
AGAIN PRESS MODE, SCREEN WILL SHOW DATE BLINKING, USE UP/DOWN KEY TO ADJUST YEAR;
AGAIN PRESS MODE, SCREEN WILL SHOW 12:00 BLINKING WITH ALARM SIGN (FOR ALARM SET);USE UP/DOWN KEYS TO SET ALARM, FIRST HOURS AND THEN MINUTES FOR ALARM; THEN ON PRESSING YOU CAN SELECT SNOOZE MINUTES;
AFTER SNOOZE ON PRESSING MODE AGAIN YOU CAN SELECT DAY COUNTDOWN TO SELECT 999 DAYS COUNTDOWN FROM CURRENT DATE;

when watch displays time and everything .....
each and every buttons has some function;(shortcuts)
press down to toggle between 12hr/24hr format;
press up to enter contdown timer;
press snooze to set snooze in alarm;
press c/f to toggle between two temperature formats;
press mode to toggle between alarm time and current time
1helpful
1answer

Why is the countdown timer not working?

Good Morning Ray, this is Z. Thank you for your question!

From what you have described it sounds like your Electrolux dryer may either have a communication error from the main control board or the timer itself may not be operating correctly. You can attempt resetting your dryer by unplugging it or flipping off the breaker for about ten minutes. If the problem still persists, it would be advisable to contact an experienced appliance repair tech to assist further.
0helpful
1answer

Bosch dishwasher SHE46C06UC won't fill with water

Check water inlet. Check for kinks in hose. Check the inline strainer in the fill solenoid. You say it makes an attempt to fill, is this because you can hear water trickling? If so I would suggest get to g the fill solenoid replaced as it may be blocked or not opening fully
Oct 27, 2017 • Dishwashers
0helpful
1answer

Having a hard time "setting" it to turn on/off

Question is not clear: Add a comment for more information.
1) Did timer work before and stop working?
If timer stopped working, then buy another one for $15.

2) Is this a new timer?
Is the wiring correct?
Does the on-off switch turn load on and off?

GE 15068 is countdown timer.
Following link has a photo showing example timer:
http://ecx.images-amazon.com/images/I/311ev7wNxkL._SL500_AA300_.jpg
To operate countdown functions, move slide switch to Timer.
Rotate dial to one of the numbers shown on dial, for example 15.
Timer will turn on Load.
Timer begins counting down for 15 minutes.
When countdown expires, load turns off.
0helpful
1answer

Despite the fans working on a plain Jane single pole switches, I can't get these 6515M switches to work for my 1.3 ceiling fans. The fan hums and all I get on the timers are red LEDs. These timers...

1) Leviton 6515 is incandescent only:
http://www.amazon.com/Leviton-6515M-I-2-5-10-15-Electronic-Incandescent/dp/B0007NOZDI

2) Below is list of countdown timers with horsepower rating so they work for fans:

GE15088 countdown timer is rated 3/4 hp
http://www.homedepot.com/webapp/wcs/stores/servlet/ProductDisplay

Intermatic spring wound countdown timers are rated for 2 horsepower
http://www.intermatic.com/products/timers/in-wall%20timers/decorator%20spring%20wound%20timers.aspx

Woods spring-wound countdown timer says bath/ ceiling fans, but doesn't give horsepower
http://waterheatertimer.org/pdf/Wood-59700-series--spring-wound.pdf
http://waterheatertimer.org/Woods-timers-and-manuals.html#countdown

Woods push-button countdown is 1/4 horsepower
http://www.amazon.com/Woods-59014-Decora-12-8-4-2-12-Hour/dp/B002C54GH4

Wattstopper RT50 at Grainger shows 1/6 horsepower rating
http://www.grainger.com/Grainger/WATT-STOPPER-Time-Switch-2HTE1?Pid=search


3) Following timers are NOT rated for fans:

Lutron MA-T51 countdown timer specifically says it cannot be used for motors.
http://www.amazon.com/Lutron-MA-T51-WH-Maestro-Countdown-Timer/dp/B001EFV1DA
http://www.lutron.com/TechnicalDocumentLibrary/0301041A.pdf

Pass and Seymour RT1 countdown does not show rating for horsepower, so this timer will probably not work for fan motor
http://www.homedepot.com/Electrical/h_d1/N-5yc1vZ1xg8Zarcd/

0helpful
1answer

I am installing the timer for a whole house fan. I hooked red up to load, black to hot and white to neutral per instructions...confirmed with meter....the timer does not seem to work..I can turn on and...

A) GE 15069 image at Amazon
http://www.amazon.com/60-minute-Automatic-Shut-Off-Timer-Switch/dp/B002DNAE7Q

15069 manual
http://www.jascoproducts.com/support/manual-downloads/applications/DocumentLibraryManager/upload/In-Wall-15069-Manual-eng.pdf

Manual shows GE 15069 countdown timer is rated up to 1/2 horsepower
Whole house fan is likely 3/4 horsepower >> check nameplate on fan motor.

B) work around:
Hook timer up to a contactor/relay.
Timer turns on 120 volt, 7 watt contactor coil.
Contactor turns on fan motor
http://waterheatertimer.org/H230A.html
Square D contactor at Grainger
http://www.grainger.com/Grainger/SQUARE-D-Compact-Contactor-5B132?Pid=search
http://www.pexsupply.com/Furnas-Controls-45EG20AF-2-Pole-30-Amp-120V-Contactor
I buy these contactors at local HVAC supply for $15
add a comment if you need help wiring this device.

C) List below shows countdown timers with horsepower rating:
GE15088 countdown timer is rated 3/4 hp
http://www.homedepot.com/webapp/wcs/stores/servlet/ProductDisplay

Intermatic spring wound countdown timers are rated for 2 horsepower
http://www.intermatic.com/products/timers/in-wall%20timers/decorator%20spring%20wound%20timers.aspx

Woods spring-wound countdown timer says bath/ ceiling fans, but doesn't give horsepower
http://waterheatertimer.org/pdf/Wood-59700-series--spring-wound.pdf
http://waterheatertimer.org/Woods-timers-and-manuals.html#countdown

Woods push-button countdown is 1/4 horsepower
http://www.amazon.com/Woods-59014-Decora-12-8-4-2-12-Hour/dp/B002C54GH4

Lutron MA-T51 countdown timer specifically says it cannot be used for motors, which says the electronics inside each device is Load specific
http://www.amazon.com/Lutron-MA-T51-WH-Maestro-Countdown-Timer/dp/B001EFV1DA
http://www.lutron.com/TechnicalDocumentLibrary/0301041A.pdf

Pass and Seymour RT1 countdown does not show rating for horsepower, so this timer will probably not work for fan motor
http://www.homedepot.com/Electrical/h_d1/N-5yc1vZ1xg8Zarcd/

Wattstopper RT50 at Grainger shows 1/6 horsepower rating
http://www.grainger.com/Grainger/WATT-STOPPER-Time-Switch-2HTE1?Pid=search
21helpful
5answers

KADIO KD-3806 Model watch. How can we set date and time.

ALL PARAMETERS CAN BE ADJUSTED BY USING KEYS

GIVEN BACKSIDE...KEYS ARE

MODE (LONG PRESS-4 SEC) TO ENTER INTO SETTINGS;

UP/DOWN TO CHANGE THE PARAMETERS; \

*C/*F KEY TO TOGGLE BETWEEN TO TEMPERATURE FORMAT;

SNOOZE BUTTON TO SET SNOOZE IN ALARM-MULTIPLE SNOOZE CAN BE SET;

RESET KEY CAN BE USED TO RESET CLOCK TO DEFAULT;

DAY COUNTDOWN , AND TIME COUNTDOWN CAN BE ADJUSTED;

DETAILED INFORMATION TO SET THE CLOCK

INSERT CELLS;-SCREEN SHOWS DEFAULT VALUES-INITIAL MUSIC WILL RING;
LONG PRESS MODE BUTTON-KEEP IT PRESSED UNTIL 12 STARTS BLINKING;
USE UP /DOWN BUTTON TO ADJUST HOURS...
THEN SIMPLY PRESS MODE AGAIN, NOW MINUTES 00 IS DEFAULT WILL START BLINKING;
USE UP/DOWN BUTTON TO ADJUST MINUTES;
AGAIN PRESS MODE, SCREEN WILL SHOW YEAR 2002 DEFAULT BLINKING, USE UP/DOWN KEY TO ADJUST YEAR;
AGAIN PRESS MODE, SCREEN WILL SHOW MONTH BLINKING, USE UP/DOWN KEY TO ADJUST CURRENT MONTH;
AGAIN PRESS MODE, SCREEN WILL SHOW DATE BLINKING, USE UP/DOWN KEY TO ADJUST YEAR;
AGAIN PRESS MODE, SCREEN WILL SHOW 12:00 BLINKING WITH ALARM SIGN (FOR ALARM SET);USE UP/DOWN KEYS TO SET ALARM, FIRST HOURS AND THEN MINUTES FOR ALARM; THEN ON PRESSING YOU CAN SELECT SNOOZE MINUTES;
AFTER SNOOZE ON PRESSING MODE AGAIN YOU CAN SELECT DAY COUNTDOWN TO SELECT 999 DAYS COUNTDOWN FROM CURRENT DATE;

when watch displays time and everything .....
each and every buttons has some function;(shortcuts)
press down to toggle between 12hr/24hr format;
press up to enter contdown timer;
press snooze to set snooze in alarm;
press c/f to toggle between two temperature formats;
press mode to toggle between alarm time and current time
Nov 12, 2010 • Watches
25helpful
2answers

How do I change time on a KADIO clock 3809

MODE (LONG PRESS-4 SEC) TO ENTER INTO SETTINGS;

UP/DOWN TO CHANGE THE PARAMETERS; \

*C/*F KEY TO TOGGLE BETWEEN TO TEMPERATURE FORMAT;

SNOOZE BUTTON TO SET SNOOZE IN ALARM-MULTIPLE SNOOZE CAN BE SET;

RESET KEY CAN BE USED TO RESET CLOCK TO DEFAULT;

DAY COUNTDOWN , AND TIME COUNTDOWN CAN BE ADJUSTED;

DETAILED INFORMATION TO SET THE CLOCK

INSERT CELLS;-SCREEN SHOWS DEFAULT VALUES-INITIAL MUSIC WILL RING;
LONG PRESS MODE BUTTON-KEEP IT PRESSED UNTIL 12 STARTS BLINKING;
USE UP /DOWN BUTTON TO ADJUST HOURS...
THEN SIMPLY PRESS MODE AGAIN, NOW MINUTES 00 IS DEFAULT WILL START BLINKING;
USE UP/DOWN BUTTON TO ADJUST MINUTES;
AGAIN PRESS MODE, SCREEN WILL SHOW YEAR 2002 DEFAULT BLINKING, USE UP/DOWN KEY TO ADJUST YEAR;
AGAIN PRESS MODE, SCREEN WILL SHOW MONTH BLINKING, USE UP/DOWN KEY TO ADJUST CURRENT MONTH;
AGAIN PRESS MODE, SCREEN WILL SHOW DATE BLINKING, USE UP/DOWN KEY TO ADJUST YEAR;
AGAIN PRESS MODE, SCREEN WILL SHOW 12:00 BLINKING WITH ALARM SIGN (FOR ALARM SET);USE UP/DOWN KEYS TO SET ALARM, FIRST HOURS AND THEN MINUTES FOR ALARM; THEN ON PRESSING YOU CAN SELECT SNOOZE MINUTES;
AFTER SNOOZE ON PRESSING MODE AGAIN YOU CAN SELECT DAY COUNTDOWN TO SELECT 999 DAYS COUNTDOWN FROM CURRENT DATE;

when watch displays time and everything .....
each and every buttons has some function;(shortcuts)
press down to toggle between 12hr/24hr format;
press up to enter contdown timer;
press snooze to set snooze in alarm;
press c/f to toggle between two temperature formats;
press mode to toggle between alarm time and current time;

Nov 08, 2010 • Watches
72helpful
1answer

Round soft key OXO Timer I need to change the clock time their model # is 1061978

Operating functions:
To set the clock, press and hold the clock/timer button for three seconds. A clock icon will appear on the left side of the screen. Input the time using the numerical buttons and then click the clock/timer button to save the time.
To set the timer, press and release the clock/timer button so that the display shows all zeroes. Enter the desired time using the keypad. Press start/stop to start the countdown. The countdown may be paused by pressing the stop/start button and resumed by pressing the same button again.
When countdown is complete, timer will beep continuously for thirty seconds and display will flash. Timer will then beep every ten seconds for ten minutes until the stop/start button is pressed.
This timer will also time up to time activities. To start count up, press clear/memory so timer reads all zeroes. Press stop/start and a plus sign will appear on the right side of the screen as the timer begins counting up.
1helpful
1answer

The dishwasher has been running for 3 hours and seems to be stuck on 1 minute left. Upon opening, there was sudsy water remaining in the bottom, but the dishes looked clean. The washer just won't go to...

SHU 53 MODELS To start test program, press and hold both SCRUB WASH and DELICATE/ECONO program buttons, then turn unit on by pressing ON/OFF button. Initially, control module version # will be displayed (e.g./ ?21? = version 1 with jumper). When wash program buttons are released, lights above them will flash. To end test program, press ON/OFF button. To check each program indicator light, press its button. To check Cycle Countdown display, Refill Rinse Agent light and REGULAR WASH light, press REGULAR WASH button (press Delay Start button to test Cycle Countdown display alone). Cycle Countdown display will show ?88″ when REGULAR WASH button is pressed and ?8h? when Delay Start button is pressed. To start testing, press both the SCRUB WASH and DELICATE/ECONO buttons a second time. When testing has ended, Cycle Countdown display will show a fault using codes below. If more than one fault occurs, code numbers will be added together, (e.g./ ?6? = faults 2 + 4). 0 = No faults detected 2 = Heating fault 8 = NTC (temperature sensor) fault 1 = Aqua Sensor (?Sensotronic?) fault 4 = Filling fault F = Filling fault (display occurs during wash, not test) To check for heater, high limit or flow switch problems, start testing until heating starts. Using a meter with a current coil, measure current going into dishwasher. If current is ~ 11 A, then heater, high limit and flow switch are OK. If current stays at ~ 1.5-2 A, then heater, high limit or flow switch are faulty. If water level switch (f1) has failed (opened), display will show fault code ?4″ and unit will continually fill and drain where testing won?t be completed. If flow switch (e5) has failed (opened), display will show ?0″, water won?t heat (to 150?F) and water won?t stop circulating. If NTC probe (f2/f4) has failed (opened), display will show fault code ?8″ immediately and testing will end shortly after water has started circulating.
Not finding what you are looking for?

281 views

Ask a Question

Usually answered in minutes!

Top Electrolux Dryers Experts

vince

Level 3 Expert

2530 Answers

Cindy Wells

Level 3 Expert

6688 Answers

NOEL
NOEL

Level 3 Expert

8606 Answers

Are you an Electrolux Dryer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...