Remove connections from hi-limit switch, and put an ohm-meter across connections then heat it with a match or heat source of that temp range,heat the face and watch your meter it will show open when hi limit reaches cutoff limit/if you need exact cutout temp,you will need to have one of those digital read-out temp gun
Posted on Jul 27, 2009
What we do if we don't get heat range suitable for heating.
http://www.thertastore.com
Posted on Oct 15, 2012
Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
Here's a link to this great service
Good luck!
Posted on Jan 02, 2017
Nov 22, 2013 | Pitco Frialator 35CS Deep Fryer
Aug 21, 2011 | Pitco Frialator 35CS Deep Fryer
Jul 21, 2011 | Pitco Frialator 35CS Deep Fryer
May 29, 2011 | Pitco Frialator 35CS Deep Fryer
Jun 14, 2010 | Pitco Frialator 35CS Deep Fryer
Feb 25, 2010 | Pitco Frialator 35CS Deep Fryer
Feb 24, 2010 | Pitco Frialator 35CS Deep Fryer
Feb 24, 2010 | Pitco Frialator 35CS Deep Fryer
Aug 15, 2009 | Pitco Frialator 35CS Deep Fryer
Jun 04, 2009 | Pitco Frialator 35C Deep Fryer
27,593 people viewed this question
Usually answered in minutes!
Yes pilot lights; fryer goes up to requird temp and shuts off. Pilot also goes out. Sometimes high temp switch has to be reset.
Will the pilot light ?
×