SOURCE: three year old coleman 5000/6250 generator. High
Your RPM's are too high. There is no voltage regulator in coleman generators (generator is actually made by generac) and is 100% dependent on engine speed. There is a screw under the tank when your looking in from the recoil side. It controls the governor arm. Screw it in and it incresses the rpm, out decrease. Plug something in that draws a decent load while setting the rpms since you want it to put out 120 and 240 underload. Your idle voltage does not matter.
Yes thats true
there is high altitude re jetting in the carburator your carb has to be re jetted for the normal operation of the generator at high altitudes by the authorised personel but when you will bring it back again at the orignal altitude it will get heated quickly and may not function properly so you will have to bring the carb settings to its orignal position so be careful