SOURCE: kyocera FS-1016MFP "printer error service
Code: 6000
Contents: Broken heater lamp error
The temperature won't rise by 1°C/33.8
°F during warming up and the heater is
turned on for 5 seconds.
The temperature won't rise by 1°C/33.8
°F during printing and the heater is
turned on for 5 seconds with the duty
cycle more than 60%.
Causes:
- Defective fuser thermistor.
- Broken thermal cutout or heater lamp.
- Defective engine/high voltage PWB.
SOURCE: hi have an error
Code: 6000
Contents: Broken fuser heater lamp wire
30 ppm model:
The temperature does not rise 1×C after
the fuser heater lamp has been turned
on continuously 5 s.
35/45 ppm models:
The temperature does not rise 1°C after
the fuser heater lamp has been turned
on continuously 5 s.
The temperature does not rise 1°C after
the fuser heater lamp has been turned
on continuously 10 s during waming-up
or at standby.
Causes:
- Poor contact in the fuser thermistor M connector terminals.
Check procedures/corrective measures:
- Reinsert the connector
Causes:
- Fuser thermistor M installed incorrectly.
Check procedures/corrective measures:
- Check and reinstall if necessary
Causes:
- Thermal cutout triggered.
Check procedures/corrective measures:
- Check for continuity. If none, replace the thermal cutout
Causes:
- Fuser heater lamp installed incorrectly
Check procedures/corrective measures:
Check and reinstall if necessary
Causes:
- Broken fuser heater lamp wire.
Check procedures/corrective measures::
- Check for continuity. If none, replace the fuser heater lamp
160 views
Usually answered in minutes!
×