SOURCE: Carrier Infinity DC motor drive problems
Contact the company that installed the unit. Its new, under warranty, Anything you do could void the warranty. If they do not take care of the problem without charges contact Carrier and tell them what's going on. The company who installed the unit is responsible for making it run correctly. Good luck. kstfas
SOURCE: 3 amp fuse blows on a carrier 58mcb furnace board
Hi!!! Does your ac unit work fine?If not check your low voltage problem..You have a low voltage problem check the wire going out to your condensor make sure that they are not touching..Good luck..Check low voltage wires..short in progress..
SOURCE: Carrier Infinity Control Programming Issue
Open the flap, and press and hold the advanced button for 10 sec. you will be in the Installer setup screen. scroll down to the setup subfolder and select thermostat and it will be in there.
SOURCE: Sensor Error on Thermostat for Carrier Infinity System
Either miswired, or incompatible components, or outdoor thermistor isnt installed or is bad
an easy fix if onsite
SOURCE: Carrier Infinity Control Thermostat SYSTXCCUID01-B
Your old stat is wired for a traditional thermostat and not a communication stat like the new infinity you have. There is a module plug on the furnace board that will need to be connected to the new thermostat for it to work. The wires that are wired now are from a terminal strip inside the furnace. Please contact your local Carrier dealer. They may be able to get that harness for you