Https://printcopy.info/?l=en&mod=erc&brand=Toshiba&model=e-Studio%20283&code=C970
C970
Description
Process related service call High-voltage transformer abnormality: Leakage of the main charger is detected.
Causes
Remedy
1. Is the main charger installed securely? 2. Check if the spring of high-voltage supply contact point is deformed. 3. Check if the needle electrode is broken or the main charger grid is deformed. 4. Check if any foreign matters is on the needle electrode or the main charger grid. 5. Check if the transfer roller and the separation needle are installed securely. 6. Check if the transfer roller or the separation needle is removed. 7. Check if there is any foreign matter attached on the transfer roller or the separation needle. Toshiba Studio 283 Error Codes
SOURCE: toshiba e studio 350
C970 indicates charging issue. Need to check the T/S block and main charger for deform/broken wires.
SOURCE: Error code C970 on my
Check if the charger wire at the side door is broken or main charger grid is deformed.
& if any foreign matters are on the charger wire or main charger grid.
SOURCE: ERROR C970 TOSHIBA E STUDIO 350
[C970] High-voltage transformer abnormality (1) Is the main charger installed securely? (2) Check if the spring of high-voltage supply contact point is deformed. (3) Check if the charger wire is broken or the main charger grid is deformed. (4) Check if any foreign matters are on the charger wire or main charger grid. (5) Is the transfer/separation charger installed securely? (6) Check if the transfer/separation charger wire is broken or unhooked.
(7) Check if any foreign matter is on the transfer/separation charger wire.
SOURCE: toshiba e-studio 232 code C970
1. Check and clean the main charger, replace if required.
2.
Check and clean the transfer/sep. unit, replace if required.
3. Before you replace the HVT board, check the black color plastic piece mounted on the machine frame where the main charger connects. If this part is damaged, the high voltage will arc through which can cause C970. (found in several machines).
SOURCE: How can i fix the
1. Check and clean the main charger, replace if required.
2. Check and clean the transfer/sep. unit, replace if required.
3. Before you replace the HVT board, check HVT connector bracket (the black color plastic piece mounted on the machine frame where the main charger connects). If this part is damaged or cracked, the high voltage will arc through this, which can cause C970. (found in several machines).
886 views
Usually answered in minutes!
×