I have the exact same error. I was told this was an error to do with the thermistor of fusing unit I have replaced the fuser and still have the same error.
The fuser code needs to be reset, this can only be done by a technician, I would bite the bullet and have someone come and reset the code also if you kept the old fuser unit you may be able to get them to replace the thermistors also for not much more.
if this answers your query please rate accordingly.
Thanks
Press total clear press 1 0 7 and press for more off 3 second the clear stop key to enter to service program mode.
Then enter SP 5-810 (SC code reset),
select execute, select close. Exit
SP mode, turn the main power
switch off then on.