Fan and condensor are on but no air volume is coming out.

Condensor motot just replaced. AC unit was fine for 1st week. Now the air volume is little to none. Happens intermittenly, not all the time. Condensor is not tripping, I checked for that.

1 Answer

Anonymous

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

  • Master 614 Answers
  • Posted on Aug 14, 2009
Anonymous
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

Joined: Jun 03, 2009
Answers
614
Questions
0
Helped
274775
Points
1717

If air volume inside is dropping could be icing up or jsut a bad fan motor. Check to see if your indoor coil is clean. You have a goodman unit and they have a time delay relay for fan control. They go out quite often. If problem continues call aservice tech for free estimate. There is only so far you can go without knowledge of he system. russ

Testimonial: "Ok I was suspecting something like that. Will check it out thanks!"

  • Anonymous Aug 14, 2009

    If air volume inside is dropping could be icing up or jsut a bad fan motor. Check to see if your indoor coil is clean. You have a goodman unit and they have a time delay relay for fan control. They go out quite often. If problem continues call aservice tech for free estimate. There is only so far you can go without knowledge of he system. russ

×

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer
0helpful
1answer

I have a 2002 dodge ram 1500 4.7L engine. Air conditioning only blows cold air when vehicle is moving; warm air when idling... please help. Thanks!

Start by checking the condensor fan to make sure it is running while you have the ac on. If it is not blowing check the condensor fan motor fuse that is located in the totally integrated power module. If the fuse is bad it is most likely that the condensor fan motor is bad and is drawing too much amperage and will need to be replaced. Now I am assuming it has an electric condensor fan motor. Make sure that the condensor is free of debris, a dirty condensor will cause high discharge pressures that will cause poor or insufficient cooling at idle.
0helpful
1answer

SPLIT AC CONDENSER TRIPS AFTER 1 OR 2 MINS, ONLY DURING THE DAY TIME

The condensor is not cooling fast enough. Try cleaning the condensor coil. Also check that the fan goes on. At night the outside temperature is cooler and does not need much work to cool down the condensor.
14helpful
1answer

Its been working great and now for the last two days it works fine the compresser kicks on but when it kicks off and trys to come back on it pops the electric breaker. its been working fine on the same...

Whether its a central air unit or a wall unit, make sure the condensor is clean and air can flow thru it
make sure the condensor fan is running, the condensor fan keeps the compressor from over heating
if the condensor fan stops running the compressor will over heat and trip the circuit breaker. good luck!
0helpful
1answer

My car keeps getting almost to the red in the temp gauge and the thermostat was already replaced I dont know what else to do

Most common problem is debris build up on the radiator front, or debris build up on the AC condensor causing no or little air flow through the radiator and AC condensor. The radiator and AC condensor must have good air flow to keep everything cool, debris on the AC condensor will cause your AC temp to be high even with a proper AC charge. If there is no debris on the radiator or AC condensor and there is no white smoke coming out of the tailpipe and no loss of coolant, I would suspect a stopped up radiator on the inside or a bad water pump, good luck, Gary
0helpful
1answer

My AC only works when the car is in motion. It blows warm air otherwise.

Sound like maybe your a/c condensor fan is not working, should come on with a/c on, the fan sit in front or back of radiator, condensor is bolted to the front of the radiator, if its not working at stops no air blows through condensor and pressure will get high and a/c wont blow cold, while driving air is running through condersor so a/c will work fine.
0helpful
1answer

Ge tpx21pr side by side refig/freezer Freezer is not cold enough

If your unit is NOT a static condensor, (the type with cooling fins and tubes on the outside of the back of the unit) If the door seals are okay and sealing properly, you might need to service the forced air condensor components located at the rear lower area, usually behind a fiber board cover. Remove the cover and look for dust on the condensor fins and fan blades. If clogged, carefully brush, vacuum, or blow the dust out, opposite the direction of the fans natural air flow direction. (You don't want to lodge the debris further into the condensor fins.)..Be sure to unplug the unit first.
1helpful
1answer

Air won't cool when the car is stopped on a 2004 chevy cavalier. car temp is normal

make sure electric coolant fan is running.if not check or replace fan relay.the coolant fan has to be running to cool down refrigerant in condensor.so refrigerant in condensor is cooled back down to high pressure liquid so it can go to evaporator.see ifcoolant fan not working.the AC is not going to cool.when you driving the condensor is cooling down from moving air when car is going.when you come to a stop.cooling fan suppose to be on so condensor gased can be cooled down.
3helpful
3answers

A/C not working, outside fan not turning without assistance

is fan spinning fast enough it has to have alot of velocity to cool condensor coils if you haft to push fan to get going its probably shot and get new motor the ac is a sealed system and hardly ever will leak freon!!!Best of Luck to You!!! :)
0helpful
1answer

Goodman CKL60-1 Condenser Fan Runs OK, then stops

check connections tightness or if you just change the connector will solve the problem that is if the motor has not burn out yet
Not finding what you are looking for?

156 views

Ask a Question

Usually answered in minutes!

Top Goodman Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Are you a Goodman Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...