The number of blinks determine the problem:
Environment Over Temperature- 1 long blink / 1 short blink
DMD Over Temperature- 1 long blink / 2 short blinks
Lamp Over Temperature- 1 long blink / 3 short blinks
Fan1 Locked- 1 long blink / 4 short blinks
Fan2 Locked- 2 long blinks / 2 short blinks
Fan3 Locked- 2 long blinks / 3 short blinks
Fan4 Locked- 2 long blinks / 4 short blinks
DMD Initial Fail- 3 long blinks / 1 short blink
Lamp Initial Fail- 3 long blinks / 2 short blinks
Ballast UART Error- 3 long blinks / 3 short blinks
Temperature Sensor Fail- 3 long blinks / 4 short blinks
Inter Lock Open- 4 long blinks / 1 short blink
any of these will result in lamp off and shutdown.
1,242 views
Usually answered in minutes!
Thanks for the info.Tried it again looking for the blinks. When the lamp first goes out i get 2 sequences of 1 long blink and 1 short blink being enviroment overtemperature however the room is at 22C.
After this it is all short blinks until the power button turns red. Any thoughts?
×