Jrichards - I hate it when that happens! It seems that power is not getting to the armature from the brushes so I would suspect that one or both of the brushes is (are) not seated properly. Did you remove the brushes to replace them or were you just inspecting them? I'd suggest removing them again and making sure the contacts are facing in the right direction to contact the armature. The concave contact face should be resting completely on the armature. If you've turned it 90 degrees too much, it wont' seat properly. I hope this helps... Howard, Burke, VA