Hi,
Dryers have a thermal fuse, which burns out when the dryer overheats; in that case the dryer will either not run at all or stop heating. The fuse is usually located on the vent duct, inside the dryer. A blown fuse will show no continuity when measured with a meter. Before replacing the fuse, make sure the blower wheel is not broken or clogged, and there is nothing blocking the venting.
It is suggested to replace a hi-limit thermostat when replacing a thermal fuse.
Check for a tripped circuit breaker or a blown fuse. Check the wall socket for power with a voltmeter or by plugging something else in.
Let us know if you were looking for something more else please accept the suggestion.
Thank You for contacting Fixya.com
If you look in the back inside of the machine where the plugin is. There is the power supply/high-voltage transformer. THis provides power to the unit. Next to it should be a fuse. Either a ceramic or a glass bus type fuse. There should be a thin wire inside of the fuse. The wires can break and then the fuse is no longer any good.