A C6000 is as follows:
Broken fixing heater wire In fixing warm-up, the time to reach
50°C/122°F exceeds 13.5 s, the time to reach 100°C/212°F exceeds 10 s, the time to reach the primary stabilization
exceeds 10 s or the time to reach the secondary stabilization exceeds 24 s.
Solution:
Fixing heater M or S installed incorrectly.
Check and reinstall if necessary.
Broken fixing heater M or S wire.
Check for continuity. If none, replace the fixing heater M or S
The heating M or S are the hologen lamps inside the unit.
You can try to reset the fuser by entering the following
10871087 this will put you in maint mode.
163 then press start and you may have to press start again. If start doesn't work then you have to press ok.
then unplug unit and wait 30 secs. and turn back on.
Hope this helps.