One of 3 possible problems,the control is faulty,you can bypass this with a jumper wire and see if it stays running, the condenser coil is dirty and is not cooling the compressor correctly and the condenser and evaporator coils need to be cleaned,i would do this first before bypassing the control,then possibly its low on refrigerant and the low pressure switch is shutting it down or the switch itself is faulty,please rate this if it helped you,thank you
I took mine apart to see if there was anything obviously wrong before I came to the internet for help. I saw this that the control could be faulty, so I unplugged that, and it runs. I assume it will just run continuously until I put a new one in??
I posted my problem/fix but not sure where it ended up. I am pretty sure it is the on/off switch as I moved the wires to the #1 and #3 poles and now it runs constantly. I have to have it running because the water heater blew out its tank indicator and flooded the basement with 300 gals of water. After sumping/dry-vac'ing, I need the dehumidifier to work! And it does. It has run great for the past 36 hours. In the Spring I will install a new 50k switch.
×