Some times the pots that you may be using are not designed for use in induction cooking. If you are, It might be the size of pot. The peeping sound might be the cook top looking for the pot. But when all else fails. Turn the stove off at the Breaker count to 12. Turn back on. Reboot. Hope one of these work.
Align the magnet on motor support. Put it a litle closer to the board.
The imbalance sensor sends a signal directly proportional to the intensity of the magnetic field strengh from magnet. Pop off the display board and locate pin 12 of 8AF C515C microcontroller, its an A/D input, reading the imbalance sensor voltage. If the voltage on it goes below 1,5 Volts, it latchs on imbalance or error 2. The correct setting point is with motor stopped, if you shake manually the motor you have errror 2. Otherwise not.
This may help you. Please give the person who answered this thread credit if this helps. http://www.fixya.com/support/t277592-bosch_classixx_condenser_drier
×