Same problem here. Indoor comes on, outdoor fan goes on but not comp. Does not even hum. Replaced cap anyway, alarm led is on and gives n quick beat every 3 seconds. The fan amps are not measured so does not matter and even if speed is too slow the comp should come on for a while until hp is too high and draws too high current.
C7-Split compressor over current. Check condenser. If full of dust, clean it. Check rpm of fan motor. If less rpm replace capacitor.