SOURCE: Imperial deep fryer model: IFS-40
Sounds like the pilot is dirty,if you have propane gas this is your issue,replace the pilot either way.
SOURCE: trying to find a replacement control Knod for the pilot on/off
Google 3wire,they should have it.
SOURCE: my imperial IFS-40 is burning the door
Is this fryer propane?It sounds like the baffles in the tank are clogged.If you remove a burner shine a light in the baffle,if you see alot of soot use a shop vac and clean it out.Let me know.
SOURCE: flame not going into heat tubes
Make sure the regulator assembly on the gas valve is for propane. Sounds like the gas pressure is too low and the flames aren't going into the burner tubes. Make sure they didn't install an appliance regulator on the back of the fryer. This is not needed as the fryer has a regulator on the gas valve. You can unscrew the cap on the regulator assembly and turn the plastic screw inside all the way in. DO not turn with alot of force. Easy does it.
Tom