This tv only a week olds,should never having this problems already.The tv should be return and get a new tv for the replacement,this tv have tv Tuner signal board or tv power supply board distrubution problems.Even when the store test it out it work,don't take that tv back.Insit they give a new tv for the replacement.
AKB circuit (automatic kine bias), the timer/standby indicator blinks for about 30 seconds then goes to the self-diagnosis function. Something is wrong with the video. Check video out, Q705, 732, 761 and other components on the C board, also check Q218, 219, 220 on the A board. In addition, unit could be in IK blanking, try turning up screen slightly.