Check dryer Terminal block prongs both outside prongs should give combined 220, and 110 each if u check 1 outside & 1 center (ground) prong. Also check house electrical outlet for full voltage.
CHECK THERMAL SHUT OFF THERMOSTAT USUALLY LOCATED ON THE BLOWER. for OHMS or resistance with a meter. Should show a closed circuit. Ohms WHEN THIS FUSE BLOWS IT WILL SHUT DOWN EVERYTHING.
NEXT Test the PUSH start switch with meter for OHMS. Should show OHMS when pushed in or on start, and no ohms or infinity when in off position.
If you hear a humming/clicking sound from motor area you more than likely have a bad motor.
Try this test out to see if u have weak windings or relay/capacitor on motor.
Open the dryer door and turn by hand the drum while machine is on ON position. And you or someone else presses the door engagement switch in. If it starts up then u have bad windings
Another thing to check is the belt safety switch. With a multi meter.
Especially if u just replaced the belt. The belt safety switch is attached to the Tensioner and motor. IT LOOKS LIKE A DOOR SWITCH SOMEWHAT a little black pc of plastic with 2 prongs going into it. Sits at bottom of motor. Under the Tensioner. Attach meter clips to the 2 prongs on switch, Then when the little white push button is pressed in it should show continuity and none when released.
Lastly check ur DOOR SWITCH for continuity with a meter when the button is pushed in the (on/Door closed position,) it may have gone bad.
https://www.youtube.com/watch?v=sTRP6kHqAFs Hey GOD IS GOOD !!!! WHICH IS WHY MY ADVICE IS FREE
Check the door switch. You should hear a click when you press and release it. I replace these switches all the time. Here is the part should you need it.
check the door switch. if the machine think the door is open, it will not start.
just locate the switch that the door would normally hit when you close it. operate it a few times with your finger. you should feel or hear a click when the switch closes. if you don't, the switch will need replaced.
other than that your timer is suspect. it is much more expensive to replace. good luck
Yank the filter out the top. Remove the 2 screws in the filter housing. Use a putty knife to pop the top and then remove the screws holding the front on. NOTE: raise up on the front panel slightly so you won't damage the bottom clips. Get the front out yer way and remove the drum. Clean out the dryer and oil the rollers and idler. Use this handy ROUTING GUIDE to see how to put the belt back.
×