I think this is a strange error code.
Let me help youWhat is the last activity that you carried out on the machine ?
Did you try reseting the machine in service mode?
If not do the following
Press Additional function,2,8,Additional function
Use < or > keys to scroll & select CLEAR. Press OK
Use < or > keys to scroll & select ALL. Press OK.
Now switch off the machine & switch on.
Did this solve your problem.
E732 Reader communication error 0001 DDI-S communication error Check on connection between the reader controller PCB and the main controller PCB, Check on the reader power supply
E002 Insufficient temperature rise of the fixing unit
0002 The non-contact thermistor fails to reach 70 deg C within 180 sec after reaching 50 deg C. Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode ( * 2 8 * ) COPIER>FUNCTION>CLEAR >ERR 0003 The non-contact thermistor fails to reach 100 deg C within 180 sec after reaching 70 deg C. 0004 The non-contact thermistor fails to reach 120 deg C within 180 sec after reaching 100 deg C. 0005 The non-contact thermistor fails to reach 140 deg C within 180 sec after reaching 120 deg C. 0006 The non-contact thermistor fails to reach 160 deg C within 180 sec after reaching 140 deg C. 0007 The non-contact thermistor fails to reach 180 deg C within 180 sec after reaching 160 deg C. 0008 The non-contact thermistor fails to reach standby temperature (normally 190 deg C) within 180 sec after reaching 180 deg C. 0101 The non-contact thermistor fails to reach 120 deg C within 300 sec after power-on. 0102 The non-contact thermistor fails to reach standby temperature (normally 190 deg C) within 300 sec after reaching 120 deg C.
IR3100CN shows error code of E000602-0202 after start up. what is the cause and how can it be fixed.