...spa the spa is tied in with a inground pool which also has an electric heatpump It sounds like the circuit board has a bad blower control relay which kicks on intermittenly. If the blower off button ...
Question about Bath Nova H530 917 Black Soaking Bath
...needs replacing There are two things you can check, there is a tranformer that plugs into the main circuit board(usually a four wire plug). Unplug and check pins for good connection and then ...
Question about EH0 / EH1 / EG9 Fuzion 6666 Corner Whirlpool with Right-Side Pump...
...pump turning off and then on again. This is a costly problem to diagnose as circuit boards start at 200.00 and go up. If it is the relay, the only way to replace one is to replace the circuit
Question about MAGNUM FORCE POOL PUMP - TWO SPEED 2 HP 115/230V
jacuzzi hot tub, aero select. pops circuit breaker as soon as switch is thrown. I disconected both motors and panel. still blows. Unit is about 8 Years old. Is there anywhere I can get a schmatic or ...
Question about RapidHeat In-Line Heater U395000 [ Bathtubs and Whirlpools,
...like the highest you are going to get it. Your only alternative is to try and rig the control circuit but I doubt anyone would want to encourage that since it involves circumventing the
Question about RapidHeat In-Line Heater U395000 [ Bathtubs and Whirlpools,
I just bought a jacuzzi j320 off a friend. For the last year it has set at 95 with a cover on a worked fine. I got the unit home hooked it up and got the water right then turned it up to 103. worked ...
Question about RapidHeat In-Line Heater U395000 [ Bathtubs and Whirlpools,
...if the pump is coming to to purge the system it sounds to me like one of the relay's on the circuit board may be out in which case you will need either a new circuit board for the control box ...
Question about Balboa R574 System for 1 2 Speed Pump Value 52221 05
...and cause the heater to operate with about a 6 amp draw. Was told to bridge out pressure switch circuit but no change. No error messages on display. From what I read the other two inputs on that ...
Question about Balboa R574 System for 1 2 Speed Pump Value 52221 05
Jacuzzi hot tub , trips the circuit breaker, inspection found a burn't part Z-1 in on wiring digram. Can some one help with what a z-1 is Capacator? Hot tub Model J-370 trips preaker, had ...
Question about Balboa R574 System for 1 2 Speed Pump Value 52221 05
...not heat and relay #3 chatters model c460000 This chattering means you have a bad relay on your circuit board. It will need to be replaced or you will need to replace the complete circuit board. ...