LG DH404E Dehumidifier. It is about 2 years old and is only run summers (May-Sept). I just went down to empty it (it's in my basement) and it was over full. The auto shut off did not work. This is the
LG dehumidifier "bucket full" light comes onand shuts down when bucket is empty. Hi, Here is a tip that I wrote to help people with just that dehumidifier problem.. Dehumidifier Problem It shows ...
dehumidifier starts up but will shut down right away Hi, It could be a bad compressor, circuit board, or maybe even a sensor or dehumidistat... Here is a tip about dehumidifiers that run but do not ...
Dehumidifier shuts off with a bucket full error when the bucket is empty. Turning the unit off for a half hour will reset the fault. This reset will allow the unit to run for about twelve hours and ...
Question about Goldstar 30-Pint Dehumidifier
Auto shut off prevents dehumidifier from working even though there is no water in container. Hi, Here is a tip that explains what can be happening to make the dehumidifier show that the bucket is full
My LHD65ELB will constantly run, it freezes up, but doesn't shut down to thaw!!!!! Hi, Here is a tip that I wrote that will help you understand why and what you cando with a dehumidifier that ices
My dehumidifier keeps shutting off when I turn it off. Its set at 35 and has worked up unitl a couple of days ago. The problem is it keeps shutting off after 1 or 2 seconds and the bucket full light ...
Question about 65 Pint Dehumidifier Auto Shut-off External Drain - LD651EBL
lg ld651ebl dehumidifier bucket full auto shut off but bucket is empty auto shut off keeps happening when the bucket full light comes on but is empty the float switch above the tank might be stuck. or
LD451EGL no water extraction My dehumidifier stopped collecting water. Everything else seems to work, there is just no water extraction. Apparently, the fans are running, but the compressor has shut ...
Question about zenith zd309 30 pint dehumidifier auto shut-off external drain
how do I put Freon in my Zenith ZD 30 dehumidifier? nothing well the gas is put in at the factory then the port is sealed shut , field addn of gas is simply not done , besides something went bad that ...